Particle size and content uniformity
- PMID: 2235898
- DOI: 10.1023/a:1015958209643
Particle size and content uniformity
Abstract
The requirements of the USP Content Uniformity test are translated into physical and mathematical parameters. Assuming spherical particle sizes with a log normal distribution, the mean particle size and particle size distribution required to insure a high probability of passing the content uniformity test are calculated. On the basis of these calculations it is shown that satisfactory tablets of low doses cannot be manufactured from a drug that does not meet certain particle size distribution specifications. It is recommended that particle size specifications for low dose drugs include a requirement for a limit to size distribution.
Comment in
-
Comments on "Particle size and content uniformity," by Yalkowsky and Bolton.Pharm Res. 1991 Aug;8(8):1076-7. doi: 10.1023/a:1015881713509. Pharm Res. 1991. PMID: 1924165 No abstract available.
-
Particle size and content uniformity.Pharm Res. 1991 Mar;8(3):419. doi: 10.1023/a:1015878506781. Pharm Res. 1991. PMID: 2052534 No abstract available.