Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Feb;15(1):E12-7.
doi: 10.1532/HSF98.20111075.

Noninvasive evaluation of coronary artery bypass grafts with 16-slice multidetector computed tomography

Affiliations
Comparative Study

Noninvasive evaluation of coronary artery bypass grafts with 16-slice multidetector computed tomography

Levent Sahiner et al. Heart Surg Forum. 2012 Feb.

Abstract

Background: The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).

Methods: Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.

Results: Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.

Conclusion: Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.

PubMed Disclaimer

Similar articles