Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Dec;40(10):907-12.
doi: 10.1016/j.ajic.2011.11.019. Epub 2012 Feb 22.

Intrinsic bacterial burden associated with intensive care unit hospital beds: effects of disinfection on population recovery and mitigation of potential infection risk

Affiliations

Intrinsic bacterial burden associated with intensive care unit hospital beds: effects of disinfection on population recovery and mitigation of potential infection risk

Hubert H Attaway 3rd et al. Am J Infect Control. 2012 Dec.

Abstract

Background: Commonly touched items are likely reservoirs from which patients, health care workers, and visitors may encounter and transfer microbes. A quantitative assessment was conducted of the risk represented by the intrinsic bacterial burden associated with bed rails in a medical intensive care unit (MICU), and how disinfection might mitigate this risk.

Methods: Bacteria present on the rails from 36 patient beds in the MICU were sampled immediately before cleaning and at 0.5, 2.5, 4.5, and 6.5 hours after cleaning. Beds were sanitized with either a bottled disinfectant (BD; CaviCide) or an automated bulk-diluted disinfectant (ABDD; Virex II 256).

Results: The majority of bacteria recovered from the bed rails in the MICU were staphylococci, but not methicillin-resistant Staphylococcus aureus. Vancomycin-resistant enterococci were recovered from 3 beds. Bottled disinfectant reduced the average bacterial burden on the rails by 99%. However, the burden rebounded to 30% of that found before disinfection by 6.5 hours after disinfection. ABDD reduced the burden by an average of 45%, but levels rebounded within 2.5 hours. The effectiveness of both disinfectants was reflected in median reductions to burden of 98% for BD and 95% for ABDD.

Conclusions: Cleaning with hospital-approved disinfectants reduced the intrinsic bacterial burden on bed rail surfaces by up to 99%, although the population, principally staphylococci, rebounded quickly to predisinfection levels.

PubMed Disclaimer

Publication types