Randomized Controlled Trial
. 2012 Sep;250(9):1261-6.
doi: 10.1007/s00417-012-1946-3. Epub 2012 Feb 25.

Short- and mid-term repeatability of macular pigment optical density measurements using spectral fundus reflectance

Affiliations
Randomized Controlled Trial

Short- and mid-term repeatability of macular pigment optical density measurements using spectral fundus reflectance

Nikolaus Dragostinoff et al. Graefes Arch Clin Exp Ophthalmol. 2012 Sep.

Abstract

Background: Several methods have been proposed for measuring macular pigment optical density (MPOD). To date, none of the realized techniques can be considered as "gold standard". A key issue for the clinical applicability of a method is its repeatability. In this study, we investigated short- and mid-term repeatability of MPOD measurements using reflectometry.

Methods: A total of 12 healthy young subjects were measured 5 times on 5 consecutive days. Repeatability over 6 months was investigated in patients with AMD. The data in AMD patients were taken from a recently published placebo controlled study investigating the effect of lutein supplementation on MPOD (n = 37; [1]). Four measurements over 6 months were used to calculate repeatability. Spectral fundus reflectance of the fovea was measured in a 2.3° detection field with a custom-built fundus reflectometer. Calculation of MPOD was based on a previously published fundus reflectance model.

Results: The coefficients of variation were 6.2 ± 2.4% and 8.0 ± 5.5% in the healthy and AMD group, respectively. Bland-Altman plots indicate that the difference between measurements at day 1 and day 5 in healthy subjects and day 1 and month 6 in AMD patients was small. The maximum deviation in MPOD in a healthy subject was 0.07 (22.6%), and 0.17 (51.5%) in a patient with AMD.

Conclusions: Reflectometry provides adequate short-term and mid-term repeatability for measuring MPOD. Accordingly, the technique makes it possible to monitor MPOD in patients with AMD and to study the influence of supplementation in these subjects. In addition, the variability of the technique is small enough to allow for clinical trials with reasonable sample size.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Arch Biochem Biophys. 2004 Oct 15;430(2):149-55 - PubMed
    1. Vision Res. 2007 Dec;47(26):3259-68 - PubMed
    1. Curr Eye Res. 2010 Apr;35(4):335-51 - PubMed
    1. Invest Ophthalmol Vis Sci. 2010 Aug;51(8):4220-5 - PubMed
    1. Invest Ophthalmol Vis Sci. 2011 Oct 17;52(11):8174-8 - PubMed

Publication types

LinkOut - more resources