Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 May;122(5):1137-41.
doi: 10.1002/lary.23223. Epub 2012 Feb 28.

Validating the clinical assessment of eustachian tube dysfunction: The Eustachian Tube Dysfunction Questionnaire (ETDQ-7)

Affiliations
Comparative Study

Validating the clinical assessment of eustachian tube dysfunction: The Eustachian Tube Dysfunction Questionnaire (ETDQ-7)

Edward D McCoul et al. Laryngoscope. 2012 May.

Abstract

Objectives/hypothesis: Eustachian tube dysfunction (ETD) is a common condition that is associated with otologic and rhinologic symptoms. The complete assessment of ETD is limited without a valid symptom score. We developed and conducted initial validation of the seven-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7), a disease-specific instrument to assess symptoms with respect to ETD.

Study design: Validation study.

Methods: The ETDQ-7 was developed using standard survey methodology. The ETDQ-7 was completed by a group of 50 consecutive adult patients diagnosed with ETD and 25 non-ETD patients who served as a control group. Tympanometry was used as a criterion standard to distinguish the two groups. A subset of respondents repeated the ETDQ-7 at a time point 4 weeks later.

Results: Content validity for the ETDQ-7 was established by focus group and review of the literature. Reliability testing indicated acceptable internal consistency for the entire instrument (Cronbach α = .71). The test-retest reliability indicated good correlation between the two questionnaires completed by the same patient 4 weeks apart (r = 0.78). The ETDQ-7 was able to discriminate between patients with ETD and those without (P < .001), indicating excellent discriminant validity.

Conclusions: The ETDQ-7 is a valid and reliable symptom score for use in adult patients with ETD that may facilitate clinical practice by highlighting the impact of ETD. Further testing is needed to determine its usefulness in assessing treatment response.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Receiver operating characteristic (ROC) curve for the seven-item Eustachian Tube Dysfunction Questionnaire in detecting eustachian tube dysfunction. Area under the curve = 100% (P <.0001).
Fig. 2
Fig. 2
Receiver operating characteristic (ROC) curve for the 22-Item Sinonasal Outcome Test in detecting eustachian tube dysfunction. Area under the curve = 84% (P < .0001).

References

    1. Bluestone CD. Eustachian Tube: Structure, Function, Role in Otitis Media. BC Decker; Hamilton, Ontario: 2005.
    1. Seibert JW, Danner CJ. Eustachian tube function and the middle ear. Otolaryngol Clin North Am. 2006;39:1221–1235. - PubMed
    1. Van Wijk R. Assessment of quality of life: advantages and pitfalls. Clin Exp Allergy Rev. 2005;5:32–35.
    1. Rosenfeld RM, Goldsmith AJ, Tetlus L, Balzano A. Quality of life for children with otitis media. Arch Otolaryngol Head Neck Surg. 1997;123:1049–1054. - PubMed
    1. Stewart MG, Witsell DL, Smith TL, Weaver EM, Yueh B, Hannley MT. Development and validation of the Nasal Obstruction Symptom Evaluation (NOSE) Scale. Otolaryngol Head Neck Surg. 2004;130:157–163. - PubMed

Publication types