Long term measurements of indoor radon equilibrium factor
- PMID: 22378208
- DOI: 10.1097/HP.0b013e31823b54aa
Long term measurements of indoor radon equilibrium factor
Erratum in
- Health Phys. 2012 Jun;102(6):709
Abstract
To provide detailed information for bronchial dose estimates, aerosol particle size distributions, and radon gas concentration, measurements were made in six residential homes and three laboratory rooms in different office buildings in the city of Ottawa. In the literature, most particle size distribution measurements are taken with samplers operating for a few days at most. In this study, the particle size samplers collected the samples from 77 to 162 d. The equilibrium factor determined from the long-term measurements ranged from 0.6 to almost 1 with an average of 0.75. Even though radon concentrations were quite different between residential setting and office buildings, the average equilibrium factor was similar in the two different indoor environments. The results suggest that at least in some basements, if they were occupied, the radon dose would be about twice as high as normally estimated from the conventional F(eq) value of 0.4.
Comment in
-
Comment on the Results of the long-term estimation of the non-equilibrium factor F = 0.75.Health Phys. 2014 Mar;106(3):428-30. doi: 10.1097/HP.0000000000000055. Health Phys. 2014. PMID: 25208023 No abstract available.
-
Reply to Thomas.Health Phys. 2014 Mar;106(3):430. doi: 10.1097/HP.0000000000000056. Health Phys. 2014. PMID: 25208024 No abstract available.