Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990;16(5):449-58.
doi: 10.1016/0301-5629(90)90167-b.

Doppler waveform pulsatility index and resistance, pressure and flow in the umbilical placental circulation: an investigation using a mathematical model

Affiliations

Doppler waveform pulsatility index and resistance, pressure and flow in the umbilical placental circulation: an investigation using a mathematical model

R S Thompson et al. Ultrasound Med Biol. 1990.

Abstract

A mathematical model of the umbilical placental circulation was used to examine the effect of different physiological variables on the pulsatility index (PI) of the umbilical artery Doppler waveform. The variables include the umbilical and placental resistances, the volume flow rate and the pressure. In the model the branching structure of the placental villous tree is considered in detail, while each arterial branch is itself represented simply using a resistor and a capacitor. Placental vascular disease is modelled as obliteration of a fraction of the terminal branches of the tree. The model umbilical artery PI depends on the ratio of the placental resistance to the umbilical artery resistance. The PI increases with vascular disease, but the rate of increase is not uniform. Initially, the placental resistance and the PI increase very slowly with vessel obliteration. Once the level of vessel obliteration has reached a large enough value--typically between 60% and 90% obliteration--the PI begins to rise sharply. A larger placental vascular bed can accommodate a greater level of vessel obliteration before this rapid PI rise begins. The umbilical artery PI also depends on the pulsatility of the input (aortic bifurcation) pressure waveform, but blood pressure variations in the physically attainable range cannot account for the very high PI values associated with fetal compromise. Physically attainable pressure waveform changes would, however, enable the fetus with substantial placental vascular disease to maintain umbilical volume flow rate, and at the same time exhibit a raised umbilical artery PI value.

PubMed Disclaimer

Publication types

LinkOut - more resources