Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Jul;86(1):55-61.
doi: 10.1016/j.contraception.2011.10.018. Epub 2012 Mar 2.

Prostate-specific antigen as a biomarker of condom failure: comparison of three laboratory assays and self-reported condom use problems in a randomized trial of female condom performance

Affiliations
Randomized Controlled Trial

Prostate-specific antigen as a biomarker of condom failure: comparison of three laboratory assays and self-reported condom use problems in a randomized trial of female condom performance

Terri Walsh et al. Contraception. 2012 Jul.

Abstract

Background: Prostate-specific antigen (PSA), a biomarker for semen exposure, may provide a more objective measure of condom failure than subject self-reports. Methods for measuring PSA vary and their comparability with respect to assessing condom performance has not been adequately evaluated. This study compared results from three different PSA assays of vaginal samples collected by subjects in a randomized clinical trial which compared the performance of female condoms.

Study design: We selected 30 pairs of pre- and post-coital vaginal samples from subjects who reported condom functionality problems or whose original PSA assay was positive. Samples were retested using three different PSA assays [quantitative enzyme-linked immunoassay (EIA), rocket immune-electrophoresis (RIE) and chromatographic immunoassay (CIA)]. We compared the proportion of condom uses where the post-coital PSA result indicated semen exposure for each of the three assays.

Results: Despite varying levels of sensitivity, the results from all three assays were remarkably consistent. Self-reported condom failures did not correlate well with positive PSA results, suggesting that exclusive reliance on either PSA or user self-report may be inadequate for assessing condom functionality.

Conclusion: In combination with user self-report of condom failure, PSA testing provides a reliable, objective marker of condom functionality. Studies based on PSA testing may improve on conventional contraceptive clinical trials by offering a more direct assessment of a condom product's ability to prevent semen exposure.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mauck CK, Doncel GF Biomarkers of Semen Exposure Clinical Working Group. Biomarkers of semen in the vagina: applications in clinical trials of contraception and prevention of sexually transmitted pathogens including HIV. Contraception. 2007;75:407–19. Epub 2007 Apr 30. - PubMed
    1. Lawson ML, Macaluso M, Bloom A, Hortin G, Hammond KR, Blackwell R. Objective markers of condom failure. Sex Transm Dis. 1998;25:427–32. - PubMed
    1. Macaluso M, Lawson L, Akers R, et al. Prostate-specific antigen in vaginal fluid as a biologic marker of condom failure. Contraception. 1999;59:195–201. - PubMed
    1. Walsh TL, Frezieres RG, Nelson AL, Wraxall BG, Clark VA. Evaluation of prostate-specific antigen as a quantifiable indicator of condom failure in clinical trials. Contraception. 1999;60:289–98. - PubMed
    1. Lawson ML, Macaluso M, Duerr A, et al. Partner characteristics, intensity of the intercourse, and semen exposure during use of the female condom. Am J Epidemiol. 2003;157:282–8. - PubMed

Publication types