Prostate-specific antigen as a biomarker of condom failure: comparison of three laboratory assays and self-reported condom use problems in a randomized trial of female condom performance
- PMID: 22386229
- PMCID: PMC4547345
- DOI: 10.1016/j.contraception.2011.10.018
Prostate-specific antigen as a biomarker of condom failure: comparison of three laboratory assays and self-reported condom use problems in a randomized trial of female condom performance
Abstract
Background: Prostate-specific antigen (PSA), a biomarker for semen exposure, may provide a more objective measure of condom failure than subject self-reports. Methods for measuring PSA vary and their comparability with respect to assessing condom performance has not been adequately evaluated. This study compared results from three different PSA assays of vaginal samples collected by subjects in a randomized clinical trial which compared the performance of female condoms.
Study design: We selected 30 pairs of pre- and post-coital vaginal samples from subjects who reported condom functionality problems or whose original PSA assay was positive. Samples were retested using three different PSA assays [quantitative enzyme-linked immunoassay (EIA), rocket immune-electrophoresis (RIE) and chromatographic immunoassay (CIA)]. We compared the proportion of condom uses where the post-coital PSA result indicated semen exposure for each of the three assays.
Results: Despite varying levels of sensitivity, the results from all three assays were remarkably consistent. Self-reported condom failures did not correlate well with positive PSA results, suggesting that exclusive reliance on either PSA or user self-report may be inadequate for assessing condom functionality.
Conclusion: In combination with user self-report of condom failure, PSA testing provides a reliable, objective marker of condom functionality. Studies based on PSA testing may improve on conventional contraceptive clinical trials by offering a more direct assessment of a condom product's ability to prevent semen exposure.
Copyright © 2012 Elsevier Inc. All rights reserved.
Similar articles
-
Comparison of self-reported female condom failure and biomarker-confirmed semen exposure.Contraception. 2019 Nov;100(5):406-412. doi: 10.1016/j.contraception.2019.07.143. Epub 2019 Aug 2. Contraception. 2019. PMID: 31381878 Free PMC article. Clinical Trial.
-
Evaluation of prostate-specific antigen as a quantifiable indicator of condom failure in clinical trials.Contraception. 1999 Nov;60(5):289-98. doi: 10.1016/s0010-7824(99)00098-0. Contraception. 1999. PMID: 10717781 Clinical Trial.
-
Prostate-specific antigen in vaginal fluid as a biologic marker of condom failure.Contraception. 1999 Mar;59(3):195-201. doi: 10.1016/s0010-7824(99)00013-x. Contraception. 1999. PMID: 10382083
-
The use of PSA as a biomarker of recent semen exposure in female reproductive health studies.J Reprod Immunol. 2021 Nov;148:103381. doi: 10.1016/j.jri.2021.103381. Epub 2021 Sep 9. J Reprod Immunol. 2021. PMID: 34563757 Review.
-
Do women using long-acting reversible contraception reduce condom use? A novel study design incorporating semen biomarkers.Infect Dis Obstet Gynecol. 2011;2011:107140. doi: 10.1155/2011/107140. Epub 2011 Aug 7. Infect Dis Obstet Gynecol. 2011. PMID: 21845022 Free PMC article. Review.
Cited by
-
Effect of lubricants and a vaginal spermicide gel on the detection of prostate specific antigen, a biomarker of semen exposure, using a quantitative (Abbott ARCHITECT) assay.Contraception. 2014 Feb;89(2):134-8. doi: 10.1016/j.contraception.2013.09.016. Epub 2013 Nov 12. Contraception. 2014. PMID: 24314911 Free PMC article.
-
Does tenofovir gel or do other microbicide products affect detection of biomarkers of semen exposure in vitro?Contraception. 2014 Aug;90(2):136-41. doi: 10.1016/j.contraception.2014.03.009. Epub 2014 Mar 25. Contraception. 2014. PMID: 24746557 Free PMC article.
-
Comparison of self-reported female condom failure and biomarker-confirmed semen exposure.Contraception. 2019 Nov;100(5):406-412. doi: 10.1016/j.contraception.2019.07.143. Epub 2019 Aug 2. Contraception. 2019. PMID: 31381878 Free PMC article. Clinical Trial.
-
Methodological lessons from clinical trials and the future of microbicide research.Curr HIV/AIDS Rep. 2013 Mar;10(1):89-102. doi: 10.1007/s11904-012-0141-9. Curr HIV/AIDS Rep. 2013. PMID: 23184582 Review.
-
Assessment of the vaginal residence time of biomarkers of semen exposure.Contraception. 2016 Nov;94(5):512-520. doi: 10.1016/j.contraception.2016.05.012. Epub 2016 May 31. Contraception. 2016. PMID: 27259675 Free PMC article. Clinical Trial.
References
-
- Mauck CK, Doncel GF Biomarkers of Semen Exposure Clinical Working Group. Biomarkers of semen in the vagina: applications in clinical trials of contraception and prevention of sexually transmitted pathogens including HIV. Contraception. 2007;75:407–19. Epub 2007 Apr 30. - PubMed
-
- Lawson ML, Macaluso M, Bloom A, Hortin G, Hammond KR, Blackwell R. Objective markers of condom failure. Sex Transm Dis. 1998;25:427–32. - PubMed
-
- Macaluso M, Lawson L, Akers R, et al. Prostate-specific antigen in vaginal fluid as a biologic marker of condom failure. Contraception. 1999;59:195–201. - PubMed
-
- Walsh TL, Frezieres RG, Nelson AL, Wraxall BG, Clark VA. Evaluation of prostate-specific antigen as a quantifiable indicator of condom failure in clinical trials. Contraception. 1999;60:289–98. - PubMed
-
- Lawson ML, Macaluso M, Duerr A, et al. Partner characteristics, intensity of the intercourse, and semen exposure during use of the female condom. Am J Epidemiol. 2003;157:282–8. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous