Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Aug;35(4):180-4.
doi: 10.1016/j.clae.2012.01.004. Epub 2012 Mar 3.

Clinical performance of an orthokeratology lens fitted with the aid of a computer software in Chinese children

Affiliations
Randomized Controlled Trial

Clinical performance of an orthokeratology lens fitted with the aid of a computer software in Chinese children

Ka Yin Chan et al. Cont Lens Anterior Eye. 2012 Aug.

Abstract

Purpose: To report the clinical performance of the orthokeratology (ortho-k) lens fitted with computer assisted system after 1-month of lens wear, in a group of children undergoing ortho-k treatment in a 2-year randomized myopic control study.

Method: Children aged 6-11 years old were fitted with the ortho-k lenses using computerized fitting. The initial myopia was 4.00-0.50 D and the initial refractive astigmatism was within 1.25 D. Lens performance, in terms of centration, myopic reduction, vision, ocular health status and lens binding incidence, was evaluated at one night, one week and one month after lens wear. Only data from the right eye was presented.

Results: The initial spherical equivalent refraction (SER) for the 51 subjects was -2.29 ± 0.81 D. The first fit success rate was 90%. The reduction of SER after one night and one week aftercare visit were 57% and 81%, respectively. At the one month visit, the mean reduction in SER was 89% with unaided logMAR visual acuity of 0.03 ± 0.11. Mild central corneal staining was found in 9-20% of the subjects at the aftercare visits. The incidences of lens binding at one night, one week and one month aftercare visits were 17%, 39% and 30%, respectively.

Conclusions: Computer assisted system for Menicon Z Night lens fitting gave a high first fit success rate. Menicon Z Night lens was effective in myopic reduction and provided stable vision after one week of lens wear. Ocular health of the subjects after lens wear was generally unremarkable.

Trial registration: ClinicalTrials.gov NCT00962208.

PubMed Disclaimer

Publication types

Associated data