MRI in patients with cardiac implantable electronic devices
- PMID: 22404775
- DOI: 10.1586/erd.11.73
MRI in patients with cardiac implantable electronic devices
Abstract
MRI is a powerful diagnostic tool; however, it is relatively contraindicated for patients with cardiovascular implantable electronic devices (CIEDs) such as pacemakers and implantable defibrillators. Several interactions with CIEDs have the potential to cause harm, and fatalities have been reported. Limited experience of MRI in patients with CIEDs under close supervision and utilizing specific scanning protocols has emerged from a small number of centers. Even then, adverse effects on the CIED have been reported. The recent development of MRI-conditional pacemaker systems and the demonstration of safe magnetic resonance scanning in a large clinical trial (EnRhythm MRI SureScan Pacing System Study) is a significant advance in the care of patients with CIEDs, opening up this important imaging modality to those previously denied it. Further development of MRI-conditional CIEDs, including implantable cardioverter-defibrillators, is expected but presents many technological challenges.
Similar articles
-
Canadian Heart Rhythm Society and Canadian Association of Radiologists consensus statement on magnetic resonance imaging with cardiac implantable electronic devices.Can J Cardiol. 2014 Oct;30(10):1131-41. doi: 10.1016/j.cjca.2014.07.010. Can J Cardiol. 2014. PMID: 25262858
-
Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.Ann Thorac Surg. 2011 Jun;91(6):2006-11. doi: 10.1016/j.athoracsur.2011.02.068. Epub 2011 Apr 30. Ann Thorac Surg. 2011. PMID: 21531377 Review.
-
Provision of MR imaging for patients with cardiac implantable electronic devices (CIEDs): a single-center experience and national survey.Ir J Med Sci. 2019 Aug;188(3):999-1004. doi: 10.1007/s11845-018-1922-y. Epub 2018 Oct 27. Ir J Med Sci. 2019. PMID: 30368645
-
Magnetic resonance imaging in non-conditional pacemakers and implantable cardioverter-defibrillators: a systematic review and meta-analysis.Europace. 2020 Feb 1;22(2):288-298. doi: 10.1093/europace/euz343. Europace. 2020. PMID: 31995177
-
Magnetic resonance imaging in patients with implantable cardiac devices.Rev Cardiovasc Med. 2008 Fall;9(4):232-8. Rev Cardiovasc Med. 2008. PMID: 19122581 Review.
Cited by
-
MRI-conditional pacemakers: current perspectives.Med Devices (Auckl). 2014 May 7;7:115-24. doi: 10.2147/MDER.S44063. eCollection 2014. Med Devices (Auckl). 2014. PMID: 24851058 Free PMC article. Review.
-
Diagnostic accuracy of low-dose dual-source cardiac computed tomography as compared to surgery in univentricular heart patients.J Cardiothorac Surg. 2018 May 16;13(1):39. doi: 10.1186/s13019-018-0729-2. J Cardiothorac Surg. 2018. PMID: 29769130 Free PMC article.
-
MRI and cardiac implantable electronic devices; current status and required safety conditions.Neth Heart J. 2014 Jun;22(6):269-76. doi: 10.1007/s12471-014-0544-x. Neth Heart J. 2014. PMID: 24733688 Free PMC article.
-
Magnetic resonance imaging conditional pacemakers: rationale, development and future directions.Indian Pacing Electrophysiol J. 2012 Sep;12(5):204-12. doi: 10.1016/s0972-6292(16)30543-5. Epub 2012 Sep 1. Indian Pacing Electrophysiol J. 2012. PMID: 23071382 Free PMC article.
-
Determining the Etiology of Internuclear Ophthalmoplegia in a Patient with a Cardiac Pacemaker and Complex Neurological Presentation.J Clin Neurol. 2018 Oct;14(4):574-576. doi: 10.3988/jcn.2018.14.4.574. Epub 2018 Sep 6. J Clin Neurol. 2018. PMID: 30198234 Free PMC article. No abstract available.