Dead space fraction changes during PEEP titration following lung recruitment in patients with ARDS
- PMID: 22417650
- DOI: 10.4187/respcare.01497
Dead space fraction changes during PEEP titration following lung recruitment in patients with ARDS
Abstract
Background: Elevated dead space fraction (the ratio of dead space to tidal volume [V(D)/V(T)]) is a feature of ARDS. PEEP can partially reverse atelectasis, prevent alveoli recollapse, and improve lung compliance and gas exchange in patients with ARDS. However, whether V(D)/V(T) variables have a close relationship with PEEP and collapse alveolar recruitment remains under recognized. Meanwhile, few clinicians titrate PEEP in consideration of changes in V(D)/V(T). Therefore, we performed the study to evaluate V(D)/V(T), arterial oxygenation, and compliance changes during PEEP titration following lung recruitment in ARDS patients.
Methods: Twenty-three ARDS patients ventilated in volume-controlled mode were enrolled in the study. Sustained inflation (40 cm H₂O, 30 s) was used as a recruitment maneuver, followed by decremental PEEP changes from 20 to 6 cm H₂O, in steps of 2 cm H₂O, and then to 0 cm H₂O. V(D)/V(T), pulmonary mechanics parameters, gas exchange parameters, and hemodynamic parameters were recorded after 20 min at each PEEP step.
Results: Compared with V(D)/V(T) at the PEEP levels of 20 cm H₂O and 0 cm H₂O, V(D)/V(T) was significantly lower at 12 cm H₂O (P = .02), and compliance of the static respiratory system (C(RS)) was significantly higher at pressure step 12/10 cm H₂O (P < .001). Compared with P(aCO₂) at the PEEP level of 20 cm H₂O, P(aCO₂) was significantly lower at 12 cm H₂O (P < .001). Arterial oxygenation values and functional residual capacity were reduced gradually during PEEP, decreasing from 20 cm H₂O to 0 cm H₂O.
Conclusions: A significant change of V(D)/V(T), compliance and arterial oxygenation could be induced by PEEP titration in subjects with ARDS. Optimal PEEP in these subjects was 12 cm H₂O, because at this pressure level the highest compliance in conjunction with the lowest V(D)/V(T) indicated a maximum amount of effectively expanded alveoli. Monitoring of V(D)/V(T) was useful for detecting lung collapse and for establishing open-lung PEEP after a recruitment maneuver.
Comment in
-
Dead space fraction: one of many choices to assess PEEP titration.Respir Care. 2013 Jul;58(7):e84-5. doi: 10.4187/respcare.02337. Respir Care. 2013. PMID: 23798663 No abstract available.
Similar articles
-
[Dead space guided positive end-expiratory pressure in patients with acute respiratory distress syndrome].Zhonghua Nei Ke Za Zhi. 2011 Nov;50(11):926-30. Zhonghua Nei Ke Za Zhi. 2011. PMID: 22333124 Chinese.
-
Transpulmonary pressure and gas exchange during decremental PEEP titration in pulmonary ARDS patients.Respir Care. 2013 May;58(5):754-63. doi: 10.4187/respcare.01977. Respir Care. 2013. PMID: 23051849
-
Compliance and dead space fraction indicate an optimal level of positive end-expiratory pressure after recruitment in anesthetized patients.Anesth Analg. 2008 Jan;106(1):175-81, table of contents. doi: 10.1213/01.ane.0000287684.74505.49. Anesth Analg. 2008. PMID: 18165575 Clinical Trial.
-
Recruitment Maneuvers and PEEP Titration.Respir Care. 2015 Nov;60(11):1688-704. doi: 10.4187/respcare.04409. Respir Care. 2015. PMID: 26493593 Review.
-
Using pressure-volume curves to set proper PEEP in acute lung injury.Nurs Crit Care. 2007 Sep-Oct;12(5):231-41. doi: 10.1111/j.1478-5153.2007.00224.x. Nurs Crit Care. 2007. PMID: 17883616 Review.
Cited by
-
Standard versus individualised positive end-expiratory pressure (PEEP) compared by electrical impedance tomography in neurocritical care: a pilot prospective single centre study.Intensive Care Med Exp. 2024 Aug 5;12(1):67. doi: 10.1186/s40635-024-00654-3. Intensive Care Med Exp. 2024. PMID: 39103646 Free PMC article.
-
Detection of optimal PEEP for equal distribution of tidal volume by volumetric capnography and electrical impedance tomography during decreasing levels of PEEP in post cardiac-surgery patients.Br J Anaesth. 2016 Jun;116(6):862-9. doi: 10.1093/bja/aew116. Br J Anaesth. 2016. PMID: 27199318 Free PMC article.
-
[Clinical experience of high-flow nasal cannula oxygen therapy in severe COVID-19 patients].Zhejiang Da Xue Xue Bao Yi Xue Ban. 2020 May 25;49(2):232-239. doi: 10.3785/j.issn.1008-9292.2020.03.13. Zhejiang Da Xue Xue Bao Yi Xue Ban. 2020. PMID: 32391670 Free PMC article. Chinese.
-
Respiratory mechanics and gas exchanges in the early course of COVID-19 ARDS: a hypothesis-generating study.Ann Intensive Care. 2020 Jul 16;10(1):95. doi: 10.1186/s13613-020-00716-1. Ann Intensive Care. 2020. PMID: 32676824 Free PMC article.
-
PEEP titration: the effect of prone position and abdominal pressure in an ARDS model.Intensive Care Med Exp. 2018 Jan 30;6(1):3. doi: 10.1186/s40635-018-0170-9. Intensive Care Med Exp. 2018. PMID: 29380160 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources