Epidemiology of pelvic inflammatory disease in parous women with special reference to intrauterine device use
- PMID: 2242362
- DOI: 10.1111/j.1471-0528.1990.tb02571.x
Epidemiology of pelvic inflammatory disease in parous women with special reference to intrauterine device use
Abstract
Up to the end of 1989, 206 parous women in the Oxford Family Planning Association contraceptive study had been referred to hospital with a first episode of pelvic inflammatory disease. Of these, 65 suffered from definite disease described as acute, 81 from definite disease not described as acute and 60 from 'other disease'. Considering all forms of disease together, referral was less common in those aged 25-29 and in those aged 45 or more than in those aged 30-44. Referral was more common in those of low social class, in those who smoked and in those who married young. All these factors were taken into account in analyses considering the effects of contraceptive methods. In these analyses, women currently using the contraceptive pill, the diaphragm, the sheath, female sterilization or an intrauterine device (IUCD) were compared with those currently using other methods or no method of contraception. IUCD ex-users were, however, placed in a separate category, irrespective of their current method of contraception. The relative risks obtained in these analyses, with 95% CI, were as follows: contraceptive pill 0.5 (0.2-0.9), diaphragm 0.6 (0.3-1.2), sheath 1.2 (0.6-2.4), female sterilization 0.7 (0.3-1.5), non-medicated IUCD 3.3 (2.3-5.0), medicated IUCD 1.8 (0.8-4.0), IUCD ex-users 1.3 (0.7-2.3). These data suggest that oral contraceptives, the diaphragm and female sterilization protect against pelvic inflammatory disease and that IUCDs increase the risk. Medicated devices, however, appear to carry only about half the risk of non-medicated devices, and the elevation of risks in IUCD ex-users appears to be small. Special analyses examined the risk associated with use of a Dalkon Shield. Among women currently using an IUCD (of any kind), those who had used a Dalkon Shield (at any time) had nearly five times as great a risk of hospital referral for pelvic inflammatory disease as those who had never used a Dalkon Shield (relative risk 4.7, 95% CI 2.1-9.0).
PIP: The epidemiology of pelvic inflammatory disease (PID) in parous women in relation to IUD use was studied. This study examines the association between age, parity, social class, cigarette smoking, and age at first marriage and the risk of hospitalization for PID. Up to the end of 1989, 206 parous women in the Oxford Family Planning contraceptive study had been referred to hospitals with a first episode of PID. Of this population, 65 had acute disease, 81 had nonacute disease, and 60 had ¿other diseases.¿ Referral was more common among women aged 30-44, of low social class, who smoked, and had married young. In the analysis of the effects of contraceptive methods, women currently using a contraceptive pill, the diaphragm, the sheath, female sterilization, or an IUD were compared with those currently using other methods or no method of contraception. The data suggest that oral contraceptives, the diaphragm, and female sterilization protect against PID and that IUDs increase the risk. However, medicated devices appear to carry only about half the risk of nonmedicated devices, and the elevation of risk in IUD ex-users appears small.
Similar articles
-
Epidemiology of endometriosis in women attending family planning clinics.BMJ. 1993 Jan 16;306(6871):182-4. doi: 10.1136/bmj.306.6871.182. BMJ. 1993. PMID: 8338516 Free PMC article.
-
Fertility following ectopic pregnancy with special reference to previous use of an intra-uterine contraceptive device (IUCD).Acta Obstet Gynecol Scand. 1987;66(2):131-5. doi: 10.3109/00016348709083034. Acta Obstet Gynecol Scand. 1987. PMID: 3618137
-
Intrauterine contraceptive device and pelvic inflammatory disease.Ann Med. 1993 Apr;25(2):171-3. doi: 10.3109/07853899309164163. Ann Med. 1993. PMID: 8489756 Review.
-
Pelvic inflammatory disease and the intrauterine contraceptive device.Int J Gynaecol Obstet. 1989 Feb;28(2):133-6. doi: 10.1016/0020-7292(89)90472-4. Int J Gynaecol Obstet. 1989. PMID: 2563699
-
The use of intrauterine contraceptive devices, pelvic inflammatory disease, and Chlamydia trachomatis infection.Am J Obstet Gynecol. 1988 Apr;158(4):956-9. doi: 10.1016/0002-9378(88)90101-9. Am J Obstet Gynecol. 1988. PMID: 3284365 Review.
Cited by
-
Contraception.BMJ. 1991 May 25;302(6787):1224-6. doi: 10.1136/bmj.302.6787.1224. BMJ. 1991. PMID: 2043843 Free PMC article. Review. No abstract available.
-
Pregnancy with an intrauterine device in situ and preterm delivery.Arch Gynecol Obstet. 1992;252(1):21-4. doi: 10.1007/BF02389602. Arch Gynecol Obstet. 1992. PMID: 1417085
-
Positive Testing for Neisseria gonorrhoeae and Chlamydia trachomatis and the Risk of Pelvic Inflammatory Disease in IUD Users.J Womens Health (Larchmt). 2015 May;24(5):354-9. doi: 10.1089/jwh.2015.5190. Epub 2015 Apr 2. J Womens Health (Larchmt). 2015. PMID: 25836384 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical