Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Aug;286(2):303-7.
doi: 10.1007/s00404-012-2292-8. Epub 2012 Mar 21.

Foley catheter versus intra-vaginal misoprostol for induction of labor in post-term gestations

Affiliations
Randomized Controlled Trial

Foley catheter versus intra-vaginal misoprostol for induction of labor in post-term gestations

Mohamed Kandil et al. Arch Gynecol Obstet. 2012 Aug.

Abstract

Objective: To investigate whether a fluid filled intra-uterine extra-amniotic Foley catheter is an effective alternative to vaginal misoprostol in inducing labor in primigravid women with post-term gestations.

Patients and methods: A prospective quasi-randomized controlled trial was designed and 100 primigravid women with post-term gestations were enrolled and equally allocated into two groups. A fluid filled intra-uterine extra-amniotic Foley catheter was inserted in women of group I. Women in group II received 25 microgram misoprostol vaginally every 4 h. Artificial rupture of membranes was performed for all women when their cervices reached 3-4 cm dilatation followed by oxytocin infusion if needed. The main primary outcome parameter was the induction to delivery interval. Results were tabulated and statistically analyzed.

Results: No significant difference was noted in any of the demographic data between both groups. The induction to delivery interval was shorter in the Foley group (897.36 ± 116.0 vs. 960.98 ± 94.18 min; P = 0.003). There were 34 cases which needed oxytocin augmentation in group I compared to 11 cases in group II (P < 0.01). Abnormal uterine activity occurred in three cases in the misoprostol group, but none in the Foley group. Ominous fetal heart rate was noted in one case in group I but three in group II.

Conclusion: Fluid filled Foley catheter seems to be superior to 25 μg vaginal misoprostol regimen, when used to induce labor in primigravidae with post-term gestations with the advantage of having a shorter induction delivery interval, but more need for oxytocin augmentation.

PubMed Disclaimer

Publication types

LinkOut - more resources