Reliability of the novel 7-joint ultrasound score: results from an inter- and intraobserver study performed by rheumatologists
- PMID: 22438306
- DOI: 10.1002/acr.21679
Reliability of the novel 7-joint ultrasound score: results from an inter- and intraobserver study performed by rheumatologists
Abstract
Objective: To assess the inter- and intraobserver reliability of 26 rheumatologists when performing the 7-joint ultrasound score (US7).
Methods: Six patients with rheumatoid arthritis were examined by 26 sonographers in 12 rater groups who performed the US7 score. The US7 score includes the clinically dominant wrist, the second and third metacarpophalangeal (MCP) and proximal interphalangeal joints, and the second and fifth metatarsophalangeal (MTP) joints, which were evaluated for synovitis, tenosynovitis/paratenonitis, and erosions from the dorsal side and palmar/plantar aspects by gray-scale and power Doppler (PD) ultrasound. Additional lateral scans were performed at the MCP2 and MTP5 joints. All of the groups repeated the examination in 4 patients in order to calculate the intraobserver reliability. The results of one group that included 2 expert sonographers were considered as the reference standard. Kappa values, median agreement rates (interobserver), and P values (intraobserver evaluation) were calculated.
Results: The median overall kappa value for detecting synovitis was 0.51, for tenosynovitis/paratenonitis was 0.57, and for erosions was 0.45. In detail, the best interobserver results were found for the detection of erosions in the MTP2 joint from the plantar aspect (κ = 1; median agreement rate 89.4%) and for PD signal detection in the palmar wrist region (κ = 0.79; median agreement rate 78.8%). Good agreement was found for detecting erosions in the MCP2 joint from the radial side (κ = 0.67; median agreement rate 77.3%).
Conclusion: The inter- and intraobserver reliability of the US7 score shows moderate to substantial kappa values and good agreements. Therefore, this ultrasound score has the potential to be an important imaging tool, including multicenter analysis to assess structural changes.
Copyright © 2012 by the American College of Rheumatology.
Similar articles
-
Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: a pilot project.Arthritis Rheum. 2009 Sep 15;61(9):1194-201. doi: 10.1002/art.24646. Arthritis Rheum. 2009. PMID: 19714611
-
Interobserver agreement in ultrasonography of the finger and toe joints in rheumatoid arthritis.Arthritis Rheum. 2003 Apr;48(4):955-62. doi: 10.1002/art.10877. Arthritis Rheum. 2003. PMID: 12687537
-
From A Formal Training Program In Musculoskeletal Ultrasound (MSUS) To A High Reproducibility for MSUS Ultrasound In Rheumatoid Arthritis.Curr Rheumatol Rev. 2018;14(3):264-270. doi: 10.2174/1573397113666170728125557. Curr Rheumatol Rev. 2018. PMID: 28758585
-
Achieving consensus in ultrasonography synovitis scoring in rheumatoid arthritis.Int J Rheum Dis. 2014 Sep;17(7):776-81. doi: 10.1111/1756-185X.12247. Epub 2013 Dec 13. Int J Rheum Dis. 2014. PMID: 24330219
-
Reliability of a consensus-based ultrasound score for tenosynovitis in rheumatoid arthritis.Ann Rheum Dis. 2013 Aug;72(8):1328-34. doi: 10.1136/annrheumdis-2012-202092. Epub 2012 Sep 14. Ann Rheum Dis. 2013. PMID: 22984169
Cited by
-
Patient-provider discordance between global assessments of disease activity in rheumatoid arthritis: a comprehensive clinical evaluation.Arthritis Res Ther. 2017 Sep 26;19(1):212. doi: 10.1186/s13075-017-1419-5. Arthritis Res Ther. 2017. PMID: 28950896 Free PMC article.
-
Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists.Clin Rheumatol. 2017 Dec;36(12):2799-2804. doi: 10.1007/s10067-017-3662-1. Epub 2017 May 5. Clin Rheumatol. 2017. PMID: 28477219
-
Clinical utility of F-18 sodium fluoride PET/CT for estimating disease activity in patients with rheumatoid arthritis.Quant Imaging Med Surg. 2021 Apr;11(4):1156-1169. doi: 10.21037/qims-20-788. Quant Imaging Med Surg. 2021. PMID: 33816157 Free PMC article.
-
[Agreement between ultrasound-detected inflammation and clinical signs in ankles and feet joints in patients with rheumatoid arthritis].Beijing Da Xue Xue Bao Yi Xue Ban. 2021 Dec 18;53(6):1037-1042. doi: 10.19723/j.issn.1671-167X.2021.06.005. Beijing Da Xue Xue Bao Yi Xue Ban. 2021. PMID: 34916678 Free PMC article. Chinese.
-
Baricitinib in the treatment of rheumatoid arthritis: clinical and ultrasound evaluation of a real-life single-centre experience.Ther Adv Musculoskelet Dis. 2021 May 10;13:1759720X211014019. doi: 10.1177/1759720X211014019. eCollection 2021. Ther Adv Musculoskelet Dis. 2021. PMID: 34025783 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous