Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 May;35(5):965-71.
doi: 10.2337/dc11-2021. Epub 2012 Mar 28.

Assessment of patient-led or physician-driven continuous glucose monitoring in patients with poorly controlled type 1 diabetes using basal-bolus insulin regimens: a 1-year multicenter study

Affiliations
Randomized Controlled Trial

Assessment of patient-led or physician-driven continuous glucose monitoring in patients with poorly controlled type 1 diabetes using basal-bolus insulin regimens: a 1-year multicenter study

Jean-Pierre Riveline et al. Diabetes Care. 2012 May.

Abstract

Objective: The benefits of real-time continuous glucose monitoring (CGM) have been demonstrated in patients with type 1 diabetes. Our aim was to compare the effect of two modes of use of CGM, patient led or physician driven, for 1 year in subjects with poorly controlled type 1 diabetes.

Research design and methods: Patients with type 1 diabetes aged 8-60 years with HbA(1c) ≥ 8% were randomly assigned to three groups (1:1:1). Outcomes for glucose control were assessed at 1 year for two modes of CGM (group 1: patient led; group 2: physician driven) versus conventional self-monitoring of blood glucose (group 3: control).

Results: A total of 257 subjects with type 1 diabetes underwent screening. Of these, 197 were randomized, with 178 patients completing the study (age: 36 ± 14 years; HbA(1c): 8.9 ± 0.9%). HbA(1c) improved similarly in both CGM groups and was reduced compared with the control group (group 1 vs. group 3: -0.52%, P = 0.0006; group 2 vs. group 3: -0.47%, P = 0.0008; groups 1 + 2 vs. group 3: -0.50%, P < 0.0001). The incidence of hypoglycemia was similar in the three groups. Patient SF-36 questionnaire physical health score improved in both experimental CGM groups (P = 0.004). Sensor consumption was 34% lower in group 2 than in group 1 (median [Q1-Q3] consumption: group 1: 3.42/month [2.20-3.91] vs. group 2: 2.25/month [1.27-2.99], P = 0.001).

Conclusions: Both patient-led and physician-driven CGM provide similar long-term improvement in glucose control in patients with poorly controlled type 1 diabetes, but the physician-driven CGM mode used fewer sensors.

Trial registration: ClinicalTrials.gov NCT00726440.

PubMed Disclaimer

Figures

Figure 1
Figure 1
HbA1c change from baseline (M0) at 3, 6, 9, and 12 months in groups 1, 2, and 3. Values are means (95% CIs). The data correspond well to the estimated mean and CI of the model. *P < 0.05 for comparisons between the two experimental groups and the control group at each time point. M, month.

References

    1. The Diabetes Control and Complications Trial Research Group The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977–986 - PubMed
    1. American Diabetes Association Standards of medical care in diabetes—2011. Diabetes Care 2011;34(Suppl. 1):S11–S61 - PMC - PubMed
    1. Bode BW, Schwartz S, Stubbs HA, Block JE. Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care 2005;28:2361–2366 - PubMed
    1. Thompson CJ, Cummings JF, Chalmers J, Gould C, Newton RW. How have patients reacted to the implications of the DCCT? Diabetes Care 1996;19:876–879 - PubMed
    1. Deiss D, Bolinder J, Riveline JP, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 2006;29:2730–2732 - PubMed

Publication types

Associated data