Bone lysis in well-fixed cemented femoral components
- PMID: 2246299
- DOI: 10.1302/0301-620X.72B6.2246299
Bone lysis in well-fixed cemented femoral components
Abstract
We have reviewed 25 cases of focal femoral osteolysis in radiographically stable, cemented femoral implants. In three hips retrieved at post-mortem from two patients, we have been able to make a detailed biomechanical and histological analysis. The interval between arthroplasty and the appearance of focal osteolysis on clinical radiographs ranged from 40 to 168 months, and in over 70% of the cases this did not appear until after five or more years. Few had significant pain and there was no relation to age, sex or original diagnosis. The most common site for osteolysis were Gruen zones 2 and 3 on the anteroposterior radiograph and zones 5 and 6 on the lateral radiograph. In 15 cases (60%), the area of osteolysis corresponded to either a defect in the cement mantle or an area of very thin cement. The rate of progression of these lesions was variable, but to date only one has progressed to gross loosening of the femoral component. The back-scatter scanning electron microscopic examination of serial sections and biomechanical testing of the post-mortem specimens demonstrated focal cement fracture around implants that were otherwise rigidly fixed. In eight cases from which tissue was available, histology showed a histiocytic reaction with evidence of particulate polymethylmethacrylate. We consider that this local fragmentation was the stimulus for local osteolysis in an otherwise stable cemented femoral component.
Similar articles
-
Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties.J Bone Joint Surg Br. 1990 Nov;72(6):971-9. doi: 10.1302/0301-620X.72B6.2246300. J Bone Joint Surg Br. 1990. PMID: 2246300
-
Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces.J Bone Joint Surg Am. 1998 Oct;80(10):1459-68. doi: 10.2106/00004623-199810000-00007. J Bone Joint Surg Am. 1998. PMID: 9801214
-
Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation.Clin Orthop Relat Res. 1990 Sep;(258):108-21. Clin Orthop Relat Res. 1990. PMID: 2203567
-
Femoral lysis after cemented hip arthroplasty.J Arthroplasty. 1988;3(4):285-97. doi: 10.1016/s0883-5403(88)80027-5. J Arthroplasty. 1988. PMID: 3071572 Review.
-
Wear particulate and osteolysis.Orthop Clin North Am. 2005 Jan;36(1):41-8, vi. doi: 10.1016/j.ocl.2004.06.015. Orthop Clin North Am. 2005. PMID: 15542121 Review.
Cited by
-
The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.Clin Orthop Relat Res. 2013 Feb;471(2):393-402. doi: 10.1007/s11999-012-2604-0. Clin Orthop Relat Res. 2013. PMID: 23070661 Free PMC article.
-
The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.J Biomed Mater Res B Appl Biomater. 2017 Aug;105(6):1685-1691. doi: 10.1002/jbm.b.33676. Epub 2016 Apr 15. J Biomed Mater Res B Appl Biomater. 2017. PMID: 27080740 Free PMC article. Review.
-
The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.J Mater Sci Mater Med. 2008 May;19(5):1935-43. doi: 10.1007/s10856-007-3273-5. Epub 2007 Oct 13. J Mater Sci Mater Med. 2008. PMID: 17934799
-
[The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].Orthopade. 2006 Jul;35(7):776-83. doi: 10.1007/s00132-006-0956-4. Orthopade. 2006. PMID: 16628398 German.
-
Similar Biomechanical Behavior in Gait Analysis between Ceramic-on-Ceramic and Ceramic-on-XLPE Total Hip Arthroplasties.Life (Basel). 2021 Dec 8;11(12):1366. doi: 10.3390/life11121366. Life (Basel). 2021. PMID: 34947897 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources