Cup containment and orientation in cemented total hip arthroplasties
- PMID: 2246305
- DOI: 10.1302/0301-620X.72B6.2246305
Cup containment and orientation in cemented total hip arthroplasties
Abstract
We reviewed the radiographs of 864 Charnley and STH (Zimmer) cemented total hip arthroplasties with a mean follow-up of seven years (maximum 16 years). Survivorship analysis was used to assess the correlation between radiographic performance and the bony containment or the coronal orientation of the acetabular cup. The cup orientation and containment were interrelated; all vertically oriented cups were completely contained, whereas 25% of more horizontal cups were only partially contained. Completely contained cups had significantly lower incidences of complete cement-bone radiolucency (p = 0.02) and of wear (p = 0.09). Vertically oriented cups had a lower incidence of continuous radiolucency than neutrally oriented cups, but this was not statistically significant (p = 0.25). Our results confirm the importance of complete bony containment, and also indicate that it is better to accept vertical orientation and obtain full bony coverage than to have a more horizontal orientation with partial containment.
Similar articles
-
Radiographic performance of two different total hip cemented arthroplasties. A survivorship analysis.Orthop Clin North Am. 1988 Jul;19(3):505-15. Orthop Clin North Am. 1988. PMID: 3380529
-
Improvement of the cement mantle of the acetabular component with bone cement spacers. A retrospective analysis of 200 cemented cups.Arch Orthop Trauma Surg. 1998;118(1-2):75-7. doi: 10.1007/s004020050315. Arch Orthop Trauma Surg. 1998. PMID: 9833111
-
Long-term radiographic changes in cemented total hip arthroplasty with six designs of femoral components.Biomaterials. 2003 Aug;24(19):3351-63. doi: 10.1016/s0142-9612(03)00187-x. Biomaterials. 2003. PMID: 12763462
-
New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.Acta Orthop Suppl. 2005 Feb;76(315):3-82. Acta Orthop Suppl. 2005. PMID: 15790289 Review.
-
The role of cemented sockets in 2004: is there one?J Arthroplasty. 2004 Jun;19(4 Suppl 1):92-4. doi: 10.1016/j.arth.2004.02.006. J Arthroplasty. 2004. PMID: 15190559 Review.
Cited by
-
New Developments of Ti-Based Alloys for Biomedical Applications.Materials (Basel). 2014 Mar 4;7(3):1709-1800. doi: 10.3390/ma7031709. Materials (Basel). 2014. PMID: 28788539 Free PMC article. Review.
-
Assessing the accuracy factors in the determination of postoperative acetabular cup orientation using hybrid 2D-3D registration.J Digit Imaging. 2010 Dec;23(6):769-79. doi: 10.1007/s10278-009-9226-4. Epub 2009 Jul 21. J Digit Imaging. 2010. PMID: 19626370 Free PMC article.
-
Early aseptic loosening of cementless monoblock acetabular components.Int Orthop. 2017 Apr;41(4):715-722. doi: 10.1007/s00264-016-3254-8. Epub 2016 Aug 10. Int Orthop. 2017. PMID: 27506571
-
Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.Int Orthop. 2013 Dec;37(12):2337-43. doi: 10.1007/s00264-013-2058-3. Epub 2013 Aug 22. Int Orthop. 2013. PMID: 23974837 Free PMC article.
-
Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.Springerplus. 2016 Jun 18;5(1):784. doi: 10.1186/s40064-016-2503-z. eCollection 2016. Springerplus. 2016. PMID: 27386270 Free PMC article.