Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 May;31(5):416-20.
doi: 10.1016/j.annfar.2012.01.029. Epub 2012 Mar 29.

[Ultrasound evaluation of the nasogastric tube position in prehospital]

[Article in French]
Affiliations

[Ultrasound evaluation of the nasogastric tube position in prehospital]

[Article in French]
P-M Brun et al. Ann Fr Anesth Reanim. 2012 May.

Abstract

Objective: To assess the feasibility and actual performance of ultrasound control in verification of the correct positioning of a nasogastric tube in pre-hospital settings.

Study type: Prospective, observational, single-centre study.

Patients and methods: Correct positioning of nasogastric tubes in patients intubated in a pre-hospital setting was verified by ultrasound and routinely compared with the results of two pre-hospital tests, namely a test involving insufflation of air through a syringe coupled with epigastric auscultation and a test involving aspiration of gastric fluid with a syringe. Routine x-ray control was carried out and compared with the pre-hospital results.

Results: Ninety-six patients were included. Mean age was 52 years (median: 53.5 years, SD: 23 years). In 83% of the patients (n=80), the nasogastric tube was located by ultrasound immediately during the insertion procedure. The mean times to ultrasound confirmation of correct positioning of the nasogastric tube were 7s (median: 2s; SD: 16s) and 19s for the syringe tests (median 19s, SD: 5s). Eight ultrasound control tests were negative. Location coupled with insufflation of air through a syringe allowed detection of the nasogastric tube in the stomach but without providing confirmation of the actual gastric position. The pre-hospital ultrasound results were confirmed by subsequent radiological controls at the hospital.

Conclusion: The ultrasound test performed in our study to verify correct positioning of a nasogastric tube is feasible in a pre-hospital setting. This technique is rapid and non-irradiating and is more sensitive and specific than the syringe tests commonly used in pre-hospital settings, and it may be performed in place of the latter tests.

PubMed Disclaimer

LinkOut - more resources