Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs
- PMID: 22471825
- DOI: 10.2460/javma.240.8.962
Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs
Abstract
Objective: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation.
Animals: 29 client-owned dogs.
Procedures: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO).
Results: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO).
Conclusions and clinical relevance: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.
Similar articles
-
Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs.J Vet Emerg Crit Care (San Antonio). 2010 Apr 1;20(2):207-15. doi: 10.1111/j.1476-4431.2010.00520.x. J Vet Emerg Crit Care (San Antonio). 2010. PMID: 20487248
-
Comparison of high definition oscillometric and Doppler ultrasonic devices for measuring blood pressure in anaesthetised cats.J Feline Med Surg. 2010 Oct;12(10):731-7. doi: 10.1016/j.jfms.2010.04.007. Epub 2010 Jul 8. J Feline Med Surg. 2010. PMID: 20615734 Free PMC article.
-
Comparison of Doppler ultrasonography and high-definition oscillometry for blood pressure measurements in healthy awake dogs.Am J Vet Res. 2010 Jul;71(7):766-72. doi: 10.2460/ajvr.71.7.766. Am J Vet Res. 2010. PMID: 20594078
-
[Non-invasive blood pressure measurement in dogs and cats].Tijdschr Diergeneeskd. 2005 Apr 1;130(7):198-201. Tijdschr Diergeneeskd. 2005. PMID: 15822444 Review. Dutch.
-
Hypertension in renal disease: diagnosis and treatment.Clin Tech Small Anim Pract. 2005 Feb;20(1):23-30. doi: 10.1053/j.ctsap.2004.12.004. Clin Tech Small Anim Pract. 2005. PMID: 15822527 Review.
Cited by
-
Comparison between the Parks Medical Doppler and the Mano Médical Vet BP Doppler for recording indirect systemic blood pressure in conscious dogs.Open Vet J. 2022 Jul-Aug;12(4):562-566. doi: 10.5455/OVJ.2022.v12.i4.19. Epub 2022 Aug 19. Open Vet J. 2022. PMID: 36118718 Free PMC article.
-
Indirect Doppler flow systolic blood pressure measurements taken with and without headphones in privately-owned, conscious dogs.PeerJ. 2019 Aug 1;7:e7440. doi: 10.7717/peerj.7440. eCollection 2019. PeerJ. 2019. PMID: 31396462 Free PMC article.
-
Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats.PLoS One. 2018 May 23;13(5):e0197332. doi: 10.1371/journal.pone.0197332. eCollection 2018. PLoS One. 2018. PMID: 29791515 Free PMC article.
-
Effects of Toceranib Phosphate on Systolic Blood Pressure and Proteinuria in Dogs.J Vet Intern Med. 2016 Jul;30(4):951-7. doi: 10.1111/jvim.13951. Epub 2016 May 6. J Vet Intern Med. 2016. PMID: 27149912 Free PMC article.
-
Oscillometric and Doppler arterial blood pressure measurement in conscious goats.Can J Vet Res. 2018 Oct;82(4):244-248. Can J Vet Res. 2018. PMID: 30363283 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous