An acoustic glucose sensor
- PMID: 22472531
- DOI: 10.1016/j.bios.2012.02.026
An acoustic glucose sensor
Abstract
In vivo glucose monitoring is required for tighter glycaemic control. This report describes a new approach to construct a miniature implantable device based on a magnetic acoustic resonance sensor (MARS). A ≈ 600-800 nm thick glucose-responsive poly(acrylamide-co-3-acrylamidophenylboronic acid) (poly(acrylamide-co-3-APB)) film was polymerised on the quartz disc (12 mm in diameter and 0.25 mm thick) of the MARS. The swelling/shrinking of the polymer film induced by the glucose binding to the phenylboronate caused changes in the resonance amplitude of the quartz disc in the MARS. A linear relationship between the response of the MARS and the glucose concentration in the range ≈ 0-15 mM was observed, with the optimum response of the MARS sensor being obtained when the polymer films contained ≈ 20 mol% 3-APB. The MARS glucose sensor also functioned under flow conditions (9 μl/min) with a response almost identical to the sensor under static or non-flow conditions. The results suggest that the MARS could offer a promising strategy for developing a small subcutaneously implanted continuous glucose monitor.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
[Subcutaneously implantable glucose sensors in patients with diabetes mellitus; still many problems].Ned Tijdschr Geneeskd. 2002 Jul 13;146(28):1313-6. Ned Tijdschr Geneeskd. 2002. PMID: 12148218 Review. Dutch.
-
Towards smart tattoos: implantable biosensors for continuous glucose monitoring.Adv Healthc Mater. 2013 Jan;2(1):43-56. doi: 10.1002/adhm.201200167. Epub 2012 Nov 26. Adv Healthc Mater. 2013. PMID: 23184404 Review.
-
Performance characterization of an abiotic and fluorescent-based continuous glucose monitoring system in patients with type 1 diabetes.Biosens Bioelectron. 2014 Nov 15;61:227-31. doi: 10.1016/j.bios.2014.05.022. Epub 2014 May 17. Biosens Bioelectron. 2014. PMID: 24906080 Clinical Trial.
-
Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.J Diabetes Sci Technol. 2015 Jul;9(4):725-38. doi: 10.1177/1932296815587938. Epub 2015 Jun 15. J Diabetes Sci Technol. 2015. PMID: 26078254 Free PMC article. Review.
-
Continuous non-invasive ophthalmic glucose sensor for diabetics.Chimia (Aarau). 2010;64(1-2):43-4. doi: 10.2533/chimia.2010.43. Chimia (Aarau). 2010. PMID: 21137683
Cited by
-
Biosensors with Boronic Acid-Based Materials as the Recognition Elements and Signal Labels.Biosensors (Basel). 2023 Aug 3;13(8):785. doi: 10.3390/bios13080785. Biosensors (Basel). 2023. PMID: 37622871 Free PMC article. Review.
-
Microfluidic microwave biosensor based on biomimetic materials for the quantitative detection of glucose.Sci Rep. 2022 Sep 24;12(1):15961. doi: 10.1038/s41598-022-20285-6. Sci Rep. 2022. PMID: 36153402 Free PMC article.
-
Solvothermal synthesis of Fe3O4 nanospheres for high-performance electrochemical non-enzymatic glucose sensor.Sci Rep. 2020 Sep 29;10(1):16026. doi: 10.1038/s41598-020-73090-4. Sci Rep. 2020. PMID: 32994458 Free PMC article.
-
Reusable, Non-Invasive, and Ultrafast Radio Frequency Biosensor Based on Optimized Integrated Passive Device Fabrication Process for Quantitative Detection of Glucose Levels.Sensors (Basel). 2020 Mar 11;20(6):1565. doi: 10.3390/s20061565. Sensors (Basel). 2020. PMID: 32168963 Free PMC article.
-
A Simple Electrochemical Route to Access Amorphous Co-Ni Hydroxide for Non-enzymatic Glucose Sensing.Nanoscale Res Lett. 2019 Apr 17;14(1):135. doi: 10.1186/s11671-019-2966-2. Nanoscale Res Lett. 2019. PMID: 30997590 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous