Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Apr;76(4):509-13.

Root canal shaping using rotary nickel-titanium files in preclinical dental education in Turkey

Affiliations
  • PMID: 22473564
Comparative Study

Root canal shaping using rotary nickel-titanium files in preclinical dental education in Turkey

Gül Çelik Ünal et al. J Dent Educ. 2012 Apr.

Abstract

The purposes of this study were to evaluate the ability of a group of third-year dental students without any endodontic clinical experience to use the ProTaper Instruments (Dentsply Maillefer) to decrease the amount of straightening of curved canals on human molar teeth and to determine the incidence of instrument fractures and instrumentation time. Thirty-one undergraduate dental students in Turkey received a training session. The students prepared a total of 144 root canals in human mandibular or maxillary molar teeth with ProTaper. Fifty-six teeth were excluded due to unreadable image, misinformation, or straight or severe curve. Using pre- and post-preparation digital radiographs, the straightening of curved root canals was investigated. Loss of working length and incidence of fracture were also noted. A total of eighty-eight curved root canals were selected. Mesiobuccal or mesiolingual roots with curvatures of between 20° and 43° as assessed by Schneider's method and working length of between 15 mm and 22.5 mm were included in the study. The means of the curved root canals before and after the instrumentation were 29.5° ± 6° and 27° ± 6.3°, respectively. The means of the working length before and after the instrumentation were 19 mm ± 2.1 mm and 18.3 mm ± 1.9 mm, respectively. A statistically significant difference between straightening of curved root canals and loss of working length was found between before and after instrumentation (p<0.000). The mean straightening of curved root canals and loss of working length after preparation with the size F1 ProTaper file were 2.5 mm ± 3.6 mm and 0.7 mm ± 0.6 mm, respectively. Only two F1 ProTaper instruments fractured at the apical level. The study concluded that rotary instruments performed adequately with inexperienced operators who received a brief structured training session.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms