Modularity of the femoral component in total hip arthroplasty
- PMID: 22474091
- DOI: 10.5435/JAAOS-20-04-214
Modularity of the femoral component in total hip arthroplasty
Abstract
Modular femoral components have been developed to aid in recreating native femoral version, limb length, and offset in total hip arthroplasty. Use of modular implants results in cost savings, as well. Inventory can be reduced while allowing intraoperative flexibility and options. With modular implants, the femoral prosthesis can be built in situ, which is helpful in minimizing incision length and surgical dissection. However, additional modular junctions are associated with increased concern for component failure through taper fretting, fatigue fracture, and local corrosion, which may contribute to elevated serum metal ion levels. The recent trend toward using larger diameter femoral heads may impart higher loads and stress than were seen previously. Although modular components offer a plethora of intraoperative options in primary and revision total hip arthroplasty, the long-term effects of these additional junctions remains unknown.
Similar articles
-
Spontaneous modular femoral head dissociation complicating total hip arthroplasty.Orthopedics. 2014 Jun;37(6):e592-5. doi: 10.3928/01477447-20140528-62. Orthopedics. 2014. PMID: 24972443
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty.J Arthroplasty. 2006 Sep;21(6):918-21. doi: 10.1016/j.arth.2005.10.014. J Arthroplasty. 2006. PMID: 16950051
-
Fracture of the modular femoral neck component in total hip arthroplasty.J Arthroplasty. 2013 Jan;28(1):196.e1-5. doi: 10.1016/j.arth.2011.05.024. Epub 2011 Jul 27. J Arthroplasty. 2013. PMID: 21798696
-
Fracture of a dual-modular femoral component at the stem-sleeve junction in a metal-on-metal total hip arthroplasty.Am J Orthop (Belle Mead NJ). 2014 Mar;43(3):E57-60. Am J Orthop (Belle Mead NJ). 2014. PMID: 24660185 Review.
-
New type of hip arthroplasty failure related to modular femoral components: breakage at the neck-stem junction.Orthop Traumatol Surg Res. 2013 Oct;99(6):741-4. doi: 10.1016/j.otsr.2013.02.010. Epub 2013 Aug 15. Orthop Traumatol Surg Res. 2013. PMID: 23953844 Review.
Cited by
-
Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants.Hip Int. 2023 Sep;33(5):916-924. doi: 10.1177/11207000221124115. Epub 2022 Sep 20. Hip Int. 2023. PMID: 36127850 Free PMC article.
-
Mid-term outcomes of revision hip arthroplasty due to titanium modular neck failure.Arch Orthop Trauma Surg. 2023 Sep;143(9):5909-5918. doi: 10.1007/s00402-023-04805-1. Epub 2023 Feb 11. Arch Orthop Trauma Surg. 2023. PMID: 36764965
-
Dissociation of Modular Total Hip Arthroplasty at the Neck-stem Interface: A Unique but Possible Complication.Cureus. 2019 Sep 2;11(9):e5556. doi: 10.7759/cureus.5556. Cureus. 2019. PMID: 31807396 Free PMC article.
-
3D printed silicon nitride, alumina, and hydroxyapatite ceramic reinforced Ti6Al4V composites - Tailored microstructures to enhance bio-tribo-corrosion and antibacterial properties.J Mech Behav Biomed Mater. 2023 Aug;144:105973. doi: 10.1016/j.jmbbm.2023.105973. Epub 2023 Jun 8. J Mech Behav Biomed Mater. 2023. PMID: 37311295 Free PMC article.
-
Bilateral Mechanically-Assisted Crevice Corrosion Resulting in Femoral Stem-Head Dissociation in Metal-on-Polyethylene Total Hip Arthroplasty.Arthroplast Today. 2021 Feb 26;8:35-39. doi: 10.1016/j.artd.2020.12.018. eCollection 2021 Apr. Arthroplast Today. 2021. PMID: 33718553 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical