. 2012 Mar;62(3):225-9.
doi: 10.4097/kjae.2012.62.3.225. Epub 2012 Mar 21.

Effects of inspired oxygen fraction in discriminating venous from arterial blood in percutaneous central venous catheterization under general anesthesia

Affiliations

Effects of inspired oxygen fraction in discriminating venous from arterial blood in percutaneous central venous catheterization under general anesthesia

Dong Yun Lim et al. Korean J Anesthesiol. 2012 Mar.

Abstract

Background: A low fraction of inspired oxygen (FiO(2)) increases venous deoxygenated hemoglobin concentrations, making the color of the blood darker. The present study was aimed to determine the effects of FiO(2) on the ability to discriminate venous from arterial blood.

Methods: One-hundred and sixty surgical patients undergoing percutaneous central venous access of the internal jugular vein were randomly assigned to receive an FiO(2) of 0.2, 0.4, 0.6, or 1.0 (n = 40 each) for at least 20 min prior to central line placement under general anesthesia. Vascular access was achieved with a 22-gauge needle; 2 ml of blood was withdrawn and shown to three physicians including the operator. Each of them was asked to identify the blood as 'arterial', 'venous' or 'not sure'. Simultaneous blood gas analysis of the samples was performed on blood taken from the puncture site and the artery after visual comparison to confirm blood's origin and hemodynamic measurements.

Results: Lowering FiO(2) progressively increased venous deoxygenated hemoglobin concentrations (2.24 ± 1.12, 3.30 ± 1.08, 3.66 ± 1.15, and 3.71 ± 1.33 g/dl) in groups having an FiO(2) of 1.0, 0.6, 0.4 and 0.2, respectively (P < 0.001), thereby facilitating the 'venous' blood identification (P < 0.001). Neither heart rate nor mean arterial pressure differed among the groups. None developed hypoxemia (percutaneous hemoglobin oxygen saturation < 90%) in any group during the study period.

Conclusions: A low FiO(2) increases venous deoxygenated hemoglobin levels, thereby facilitating the recognition by clinicians of its venous origin in percutaneous central venous catheterization under general anesthesia.

Keywords: Central venous catheter techniques; Complication; Inspired oxygen fraction.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Distribution of the number of patients identified by three, two or one inspectors in patients receiving different inspired oxygen fractions (FiO2) during central line placement. 3V, 2V, 1V and 0V represent 3, 2, 1, and 0 physicians discriminated venous as venous blood, respectively. *P < 0.001 compared with 1.0.

Similar articles

Cited by

References

    1. McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123–1133. - PubMed
    1. Domino KB, Bowdle TA, Posner KL, Spitellie PH, Lee LA, Cheney FW. Injuries and liability related to central vascular catheters: a closed claim analysis. Anesthesiology. 2004;100:1411–1418. - PubMed
    1. Jobes DR, Schwartz AJ, Greenhow DE, Stephenson LW, Ellison N. Safer jugular vein cannulation: recognition of arterial puncture and preferential use of the external jugular route. Anesthesiology. 1983;59:353–355. - PubMed
    1. Guilbert MC, Elkouri S, Bracco D, Corriveau MM, Beaudoin N, Dubois MJ, et al. Arterial trauma during central venous catheter insertion: Case series, review and proposed algorithm. J Vasc Surg. 2008;48:918–925. - PubMed
    1. Neustein SM, Narang J, Bronheim D. Use of the color test for safer internal jugular vein cannulation. Anesthesiology. 1992;76:1062. - PubMed