Clear and complete documentation of the physical parameters of total body irradiation (TBI) is one of the essential requirements for the evaluation and improvement of the clinical results of TBI. Concerning the dosimetric aspects of TBI, a number of recommendations have been formulated with emphasis on basic dosimetry, patient dosimetry and dose specification. The dosimeters should be calibrated regularly with reference to the absorbed dose in water. Depth dose measurements should be performed in water equivalent phantoms of specified dimensions. It has been strongly suggested to measure the absorbed dose at the surface of the patient at 8 different regions at the entry and exit of the beam under TBI conditions. The reference dose to the patient should be specified as the total dose to mid abdomen at the height of the umbilicus. As an independent parameter, the lung dose should be specified as the mean dose in the central region of the shielded part of both lungs. Recent, more complete, information on the physical and dosimetric aspects of TBI will be incorporated in the registry of the European Bone Marrow Transplant Group (EBMT). A cooperation has been established between the EBMT and the European Late Effects Project Group (EULEP) to study the development of late effects in man caused by ionising radiation.
Similar articles
-
Dosimetry for total body irradiation.Radiother Oncol. 1990;18 Suppl 1:16-29. doi: 10.1016/0167-8140(90)90175-v. Radiother Oncol. 1990. PMID: 2123356
-
Techniques applied for total body irradiation.Radiother Oncol. 1990;18 Suppl 1:10-5. doi: 10.1016/0167-8140(90)90174-u. Radiother Oncol. 1990. PMID: 2247629 Review.
-
Dosimetry in translation total body irradiation technique: a computer treatment planning approach and an experimental study concerning lung sparing.J BUON. 2008 Apr-Jun;13(2):253-62. J BUON. 2008. PMID: 18555474
-
Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom.Med Phys. 2010 Dec;37(12):6292-9. doi: 10.1118/1.3496355. Med Phys. 2010. PMID: 21302785
-
The influence of total dose, fractionation, dose rate, and distribution of total body irradiation on bone marrow transplantation.Semin Oncol. 1993 Aug;20(4 Suppl 4):3-10; quiz 11. Semin Oncol. 1993. PMID: 8342073 Review.
Cited by
-
Whole body radiotherapy: A TBI-guideline.J Med Phys. 2006 Jan;31(1):5-12. doi: 10.4103/0971-6203.25664. J Med Phys. 2006. PMID: 21206634 Free PMC article.
-
Total body irradiation-an attachment free sweeping beam technique.Radiat Oncol. 2016 Jun 10;11:81. doi: 10.1186/s13014-016-0658-y. Radiat Oncol. 2016. PMID: 27287010 Free PMC article.
-
Twenty years of experience of a tertiary cancer center in total body irradiation with focus on oncological outcome and secondary malignancies.Strahlenther Onkol. 2022 Jun;198(6):547-557. doi: 10.1007/s00066-022-01914-5. Epub 2022 Mar 22. Strahlenther Onkol. 2022. PMID: 35318487 Free PMC article.
-
Computer-based anthropometrical system for total body irradiation.Med Biol Eng Comput. 1997 May;35(3):291-4. doi: 10.1007/BF02530054. Med Biol Eng Comput. 1997. PMID: 9246868
MeSH terms