. 2012 Dec;112(12):4063-8.
doi: 10.1007/s00421-012-2391-z. Epub 2012 Apr 3.

Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis?

Affiliations

Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis?

C Balestra et al. Eur J Appl Physiol. 2012 Dec.

Abstract

One of the possible risks incurred while diving is inert gas narcosis (IGN), yet its mechanism of action remains a matter of controversy. Although providing insights in the basic mechanisms of IGN, research has been primarily limited to animal studies. A human study, in real diving conditions, was needed. Twenty volunteers within strict biometrical criteria (male, age 30-40 years, BMI 20-23, non smoker) were selected. They performed a no-decompression dive to a depth of 33 mfw for 20 min and were assessed by the means of critical flicker fusion frequency (CFFF) measurement before the dive, during the dive upon arriving at the bottom, 5 min before the ascent, and 30 min after surfacing. After this late measurement, divers breathed oxygen for 15 min and were assessed a final time. Compared to the pre-dive value the mean value of each measurement was significantly different (p < 0.001). An increase of CFFF to 104 ± 5.1 % upon arriving to the bottom is followed by a decrease to 93.5 ± 4.3 %. This impairment of CFFF persisted 30 min after surfacing, still decreased to 96.3 ± 8.2 % compared to pre-dive CFFF. Post-dive measures made after 15 min of oxygen were not different from control (without nitrogen supersaturation), 124.4 ± 10.8 versus 124.2 ± 3.9 %. This simple study suggests that IGN (at least partially) depends on gas-protein interactions and that the cerebral impairment persists for at least 30 min after surfacing. This could be an important consideration in situations where precise and accurate judgment or actions are essential.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Diving Hyperb Med. 2010 Sep;40(3):114-8 - PubMed
    1. Percept Mot Skills. 1994 Dec;79(3 Pt 1):1235-8 - PubMed
    1. Am J Physiol Lung Cell Mol Physiol. 2003 Dec;285(6):L1184-9 - PubMed
    1. Undersea Hyperb Med. 2006 May-Jun;33(3):169-74 - PubMed
    1. Exp Neurol. 2008 Jul;212(1):63-70 - PubMed

LinkOut - more resources