Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis?
- PMID: 22476770
- DOI: 10.1007/s00421-012-2391-z
Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis?
Abstract
One of the possible risks incurred while diving is inert gas narcosis (IGN), yet its mechanism of action remains a matter of controversy. Although providing insights in the basic mechanisms of IGN, research has been primarily limited to animal studies. A human study, in real diving conditions, was needed. Twenty volunteers within strict biometrical criteria (male, age 30-40 years, BMI 20-23, non smoker) were selected. They performed a no-decompression dive to a depth of 33 mfw for 20 min and were assessed by the means of critical flicker fusion frequency (CFFF) measurement before the dive, during the dive upon arriving at the bottom, 5 min before the ascent, and 30 min after surfacing. After this late measurement, divers breathed oxygen for 15 min and were assessed a final time. Compared to the pre-dive value the mean value of each measurement was significantly different (p < 0.001). An increase of CFFF to 104 ± 5.1 % upon arriving to the bottom is followed by a decrease to 93.5 ± 4.3 %. This impairment of CFFF persisted 30 min after surfacing, still decreased to 96.3 ± 8.2 % compared to pre-dive CFFF. Post-dive measures made after 15 min of oxygen were not different from control (without nitrogen supersaturation), 124.4 ± 10.8 versus 124.2 ± 3.9 %. This simple study suggests that IGN (at least partially) depends on gas-protein interactions and that the cerebral impairment persists for at least 30 min after surfacing. This could be an important consideration in situations where precise and accurate judgment or actions are essential.
Similar articles
-
Early detection of diving-related cognitive impairment of different nitrogen-oxygen gas mixtures using critical flicker fusion frequency.Diving Hyperb Med. 2019 Jun 30;49(2):119-126. doi: 10.28920/dhm49.2.119-126. Diving Hyperb Med. 2019. PMID: 31177518 Free PMC article.
-
Assessment of Alertness and Cognitive Performance of Closed Circuit Rebreather Divers With the Critical Flicker Fusion Frequency Test in Arctic Diving Conditions.Front Physiol. 2021 Aug 10;12:722915. doi: 10.3389/fphys.2021.722915. eCollection 2021. Front Physiol. 2021. PMID: 34447319 Free PMC article.
-
Inert gas narcosis in scuba diving, different gases different reactions.Eur J Appl Physiol. 2019 Jan;119(1):247-255. doi: 10.1007/s00421-018-4020-y. Epub 2018 Oct 22. Eur J Appl Physiol. 2019. PMID: 30350155
-
Assessing Critical Flicker Fusion Frequency: Which Confounders? A Narrative Review.Medicina (Kaunas). 2023 Apr 20;59(4):800. doi: 10.3390/medicina59040800. Medicina (Kaunas). 2023. PMID: 37109758 Free PMC article. Review.
-
Recreational technical diving part 1: an introduction to technical diving methods and activities.Diving Hyperb Med. 2013 Jun;43(2):86-93. Diving Hyperb Med. 2013. PMID: 23813462 Review.
Cited by
-
Critical Flicker Fusion Frequency: A Marker of Cerebral Arousal During Modified Gravitational Conditions Related to Parabolic Flights.Front Physiol. 2018 Oct 2;9:1403. doi: 10.3389/fphys.2018.01403. eCollection 2018. Front Physiol. 2018. PMID: 30333762 Free PMC article.
-
Critical flicker fusion frequency: confounders and caveats.Eur J Appl Physiol. 2025 Aug 27. doi: 10.1007/s00421-025-05935-7. Online ahead of print. Eur J Appl Physiol. 2025. PMID: 40864284
-
Critical Flicker Fusion Frequency: A Narrative Review.Medicina (Kaunas). 2021 Oct 13;57(10):1096. doi: 10.3390/medicina57101096. Medicina (Kaunas). 2021. PMID: 34684133 Free PMC article. Review.
-
Early detection of diving-related cognitive impairment of different nitrogen-oxygen gas mixtures using critical flicker fusion frequency.Diving Hyperb Med. 2019 Jun 30;49(2):119-126. doi: 10.28920/dhm49.2.119-126. Diving Hyperb Med. 2019. PMID: 31177518 Free PMC article.
-
Assessment of Alertness and Cognitive Performance of Closed Circuit Rebreather Divers With the Critical Flicker Fusion Frequency Test in Arctic Diving Conditions.Front Physiol. 2021 Aug 10;12:722915. doi: 10.3389/fphys.2021.722915. eCollection 2021. Front Physiol. 2021. PMID: 34447319 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources