Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach
- PMID: 22481799
- DOI: 10.1109/TBME.2012.2191782
Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach
Abstract
Minimally invasive continuous glucose monitoring (CGM) sensors can greatly help diabetes management. Most of these sensors consist of a needle electrode, placed in the subcutaneous tissue, which measures an electrical current exploiting the glucose-oxidase principle. This current is then transformed to glucose levels after calibrating the sensor on the basis of one, or more, self-monitoring blood glucose (SMBG) samples. In this study, we design and test a real-time signal-enhancement module that, cascaded to the CGM device, improves the quality of its output by a proper postprocessing of the CGM signal. In fact, CGM sensors measure glucose in the interstitium rather than in the blood compartment. We show that this distortion can be compensated by means of a regularized deconvolution procedure relying on a linear regression model that can be updated whenever a pair of suitably sampled SMBG references is collected. Tests performed both on simulated and real data demonstrate a significant accuracy improvement of the CGM signal. Simulation studies also demonstrate the robustness of the method against departures from nominal conditions, such as temporal misplacement of the SMBG samples and uncertainty in the blood-to-interstitium glucose kinetic model. Thanks to its online capabilities, the proposed signal-enhancement algorithm can be used to improve the performance of CGM-based real-time systems such as the hypo/hyper glycemic alert generators or the artificial pancreas.
Similar articles
-
An online failure detection method of the glucose sensor-insulin pump system: improved overnight safety of type-1 diabetic subjects.IEEE Trans Biomed Eng. 2013 Feb;60(2):406-16. doi: 10.1109/TBME.2012.2227256. Epub 2012 Nov 15. IEEE Trans Biomed Eng. 2013. PMID: 23193300
-
Diabetes technology and treatments in the paediatric age group.Int J Clin Pract Suppl. 2011 Feb;(170):76-82. doi: 10.1111/j.1742-1241.2010.02582.x. Int J Clin Pract Suppl. 2011. PMID: 21323816 Review.
-
Online denoising method to handle intraindividual variability of signal-to-noise ratio in continuous glucose monitoring.IEEE Trans Biomed Eng. 2011 Sep;58(9):2664-71. doi: 10.1109/TBME.2011.2161083. Epub 2011 Jun 30. IEEE Trans Biomed Eng. 2011. PMID: 21724499
-
Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies.Diabetes Technol Ther. 2016 Feb;18 Suppl 2(Suppl 2):S223-33. doi: 10.1089/dia.2015.0380. Diabetes Technol Ther. 2016. PMID: 26784126 Free PMC article.
-
Real-time glucose sensors in children and adolescents with type-1 diabetes.Horm Res. 2008;70(4):193-202. doi: 10.1159/000151592. Epub 2008 Sep 5. Horm Res. 2008. PMID: 18772591 Review.
Cited by
-
Italian contributions to the development of continuous glucose monitoring sensors for diabetes management.Sensors (Basel). 2012 Oct 12;12(10):13753-80. doi: 10.3390/s121013753. Sensors (Basel). 2012. PMID: 23202020 Free PMC article. Review.
-
Quantitative estimation of insulin sensitivity in type 1 diabetic subjects wearing a sensor-augmented insulin pump.Diabetes Care. 2014;37(5):1216-23. doi: 10.2337/dc13-1120. Epub 2013 Dec 6. Diabetes Care. 2014. PMID: 24319120 Free PMC article.
-
Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges.Sensors (Basel). 2016 Dec 9;16(12):2093. doi: 10.3390/s16122093. Sensors (Basel). 2016. PMID: 27941663 Free PMC article. Review.
-
Predicting Plasma Glucose From Interstitial Glucose Observations Using Bayesian Methods.J Diabetes Sci Technol. 2014 Mar;8(2):321-330. doi: 10.1177/1932296814523878. Epub 2014 Mar 6. J Diabetes Sci Technol. 2014. PMID: 24876584 Free PMC article.
-
Differences Between Flash Glucose Monitor and Fingerprick Measurements.Biosensors (Basel). 2018 Oct 17;8(4):93. doi: 10.3390/bios8040093. Biosensors (Basel). 2018. PMID: 30336581 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical