Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Oct;54(4):427-31.

Serodiagnosis of pleuropneumonia using enzyme-linked immunosorbent assay with capsular polysaccharide antigens of Actinobacillus pleuropneumoniae serotypes 1, 2, 5 and 7

Affiliations

Serodiagnosis of pleuropneumonia using enzyme-linked immunosorbent assay with capsular polysaccharide antigens of Actinobacillus pleuropneumoniae serotypes 1, 2, 5 and 7

J T Bossé et al. Can J Vet Res. 1990 Oct.

Abstract

Capsular polysaccharide antigens of serotypes 1, 2, 5 and 7 of Actinobacillus pleuropneumoniae were used in enzyme-linked immunosorbent assays (ELISAs) to test sera from experimentally infected and field pigs. Specific reactions were found in sera of experimental pigs with antigens of serotypes 1, 5 and 7 whereas the serotype 2 antigen was cross-reactive. A 1:200 serum dilution was used for testing of 300 sera from 21 swine herds in southern Ontario. Cases of pleuropneumonia had occurred in 11 of these herds, but not in the others. The negative cut-off value was the mean optical density at 405 nm (OD405) + three standard deviations (SD) for 16 negative reference sera. Sera from four pigs naturally infected with Actinobacillus suis were tested and found to react to varying degrees with each of the antigens. Therefore a second cut-off value was determined as the mean OD405 + 2 SD for the A. suis sera. Sera which, in the ELISA produced OD readings above the latter cut-off were considered positive for antibodies to A. pleuropneumoniae; those which were lower than the former cut-off were considered negative. Readings between the two cut-off values may have been due to low positive titers or cross-reactivity, possibly with A. suis, and could not be used to predict pleuropneumonia. Of the pleuropneumonia-free herds, none had positive reactors to serotypes 5 or 7, whereas one and two herds had positive reactors to serotypes 1 and 2, respectively. Of the pleuropneumonia positive herds, six had positive reactors to serotype 1, one to serotype 2, four to serotype 5, and eight to serotype 7.

PubMed Disclaimer

References

    1. Can Vet J. 1989 Dec;30(12):943-7 - PubMed
    1. Eur J Biochem. 1987 Dec 30;170(1-2):185-92 - PubMed
    1. Can J Comp Med. 1983 Jan;47(1):1-5 - PubMed
    1. Can J Comp Med. 1982 Apr;46(2):109-14 - PubMed
    1. Vet Immunol Immunopathol. 1987 Dec;17(1-4):441-52 - PubMed

Publication types

MeSH terms

Substances

LinkOut - more resources