Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Apr;103(2):111-22.

Efficacy and safety of 10% HES 130/0.4 versus 10% HES 200/0.5 for plasma volume expansion in cardiac surgery patients

Affiliations
  • PMID: 22513516
Randomized Controlled Trial

Efficacy and safety of 10% HES 130/0.4 versus 10% HES 200/0.5 for plasma volume expansion in cardiac surgery patients

C Ertmer et al. Minerva Med. 2012 Apr.

Abstract

Aim: Hydroxyethyl starch (HES) solutions are frequently used for perioperative volume replacement. Whereas older HES specimen tended to accumulate in the plasma and to cause negative effects on hemostasis, more recent products, e.g., HES 130/0.4, are characterised by improved pharmacological properties. The present study was designed to compare the efficacy and safety of 10% HES 130/0.4 and 10% HES 200/0.5.

Methods: In this post-hoc analysis of a prospective, randomised, double-blind, multi-center therapeutic equivalence trial, 76 patients undergoing elective on-pump cardiac surgery received perioperative volume replacement using either 10% HES 130/0.4 (N.=37) or 10% HES 200/0.5 (N.=39) up to a maximum dose of 20 mL kg-1.

Results: Equivalent volumes of investigational medication were infused until 24 hours after the first administration (1577 vs. 1540 mL; treatment difference 37 [-150; 223] mL; P<0.0001 for equivalence). Whereas standard laboratory tests of coagulation were comparable between groups, von Willebrand factor activity on the first postoperative morning tended to be higher following treatment with 10% HES 130/0.4 as compared to 10% HES 200/0.5 (P=0.025) with this difference being statistically significant only in the per-protocol analysis (P=0.02). Treatment groups were comparable concerning other safety parameters and the incidence of adverse drug reactions. In particular, renal function was well preserved in both groups.

Conclusion: Ten percent HES 130/0.4 was equally effective and safe as compared to 10% HES 200/0.5 for volume therapy in patients undergoing cardiovascular surgery. Postoperative coagulation and renal function, as measured by standard laboratory tests, were similar among groups.

PubMed Disclaimer

Publication types

LinkOut - more resources