. 2012 May;38(5):840-8.
doi: 10.1016/j.jcrs.2011.11.048.

Straylight measurements as an indication for cataract surgery

Affiliations

Straylight measurements as an indication for cataract surgery

Ivanka J E van der Meulen et al. J Cataract Refract Surg. 2012 May.

Abstract

Purpose: To assess adding straylight measurements to the indication for cataract surgery.

Setting: Onze Lieve Vrouwe Hospital, Amsterdam, and Zonnestraal Eye Clinic, Hilversum, The Netherlands.

Design: Prospective interventional cohort study.

Methods: Before and after cataract extraction, corrected distance visual acuity (CDVA) and straylight were recorded in all patients. Subjective complaints were documented by the 39-item National Eye Institute Visual Function Questionnaire (NEI VFQ-39) and a straylight questionnaire.

Results: The population comprised 217 patients with a mean age of 72 years ± 9.12 (SD) (range 29 to 90 years). Preoperatively, the mean straylight was 1.55 ± 0.29 log(s) and the mean CDVA, 0.28 ± 0.21 logMAR. Visual acuity and straylight showed little correlation (R(2) = 0.08). The mean postoperative improvement in CDVA was 0.26 ± 0.20 logMAR (range -0.12 to 1.12 logMAR) and in straylight, 0.31 ± 0.32 log(s) (range -0.50 to 1.27 log[s]). The preoperative breakeven point (50% chance of postoperative improvement) was 0.06 logMAR for CDVA and 1.29 log(s) for straylight. Preoperative and postoperative questionnaires showed straylight had almost the same influence as visual acuity on quality of vision.

Conclusions: Straylight and visual acuity measure different aspects of quality of vision and influenced subjective visual quality almost equally. When straylight was added to preoperative considerations of cataract extraction, postoperative results were more predictable.

Financial disclosure: The Netherlands Academy of Arts and Sciences has a proprietary interest in the C-Quant Straylight meter. No author has a financial or proprietary interest in any material or method mentioned.

PubMed Disclaimer

Publication types

MeSH terms