Randomized Controlled Trial
. 2012 Jul;56(6):755-61.
doi: 10.1111/j.1399-6576.2012.02693.x. Epub 2012 Apr 23.

Intubation of the morbidly obese patient: GlideScope(®) vs. Fastrach™

Affiliations
Randomized Controlled Trial

Intubation of the morbidly obese patient: GlideScope(®) vs. Fastrach™

M Ydemann et al. Acta Anaesthesiol Scand. 2012 Jul.

Abstract

Background: Several potential problems can arise from airway management in morbidly obese patients, including difficult mask ventilation and difficult intubation. We hypothesised that endotracheal intubation of morbidly obese patients would be more rapid using the GlideScope(®) (GS) (Verathon Inc Corporate Headquarters, Bothell, WA, USA) than with the Fastrach™ (FT) (The Laryngeal Mask Company Ltd, Le Rocher, Victoria, Mahe, Seychelles).

Methods: One hundred patients who were scheduled for bariatric surgery were randomised to tracheal intubation using either a GS or an FT. The inclusion criteria were age 18-60 years and a body mass index of ≥ 35 kg/m(2) . The primary end point was intubation time, and if intubation was not achieved after two attempts, the other method was used for the third attempt.

Results: The mean intubation time was 49 s using the GS and 61 s using the FT (P = 0.86). A total of 92% and 84% of the patients were intubated on the first attempt using the GS and the FT, respectively. One tracheal intubation failed on the second attempt when the GS was used, and five failed on the second attempt when the FT was used. There were no incidents of desaturation and no differences between the groups in terms of mucosal damage or intubation difficulty. We experienced one oesophageal intubation using GS and six oesophageal intubations in five patients using FT. There was no difference between the pain scores or incidence of post-operative hoarseness associated with the two intubation techniques.

Conclusion: No significant difference between the two methods was found. The GS and the FT may therefore be considered to be equally good when intubating morbidly obese patients.