Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Aug 20;167(4):1360-5.
doi: 10.1016/j.ijcard.2012.04.005. Epub 2012 Apr 24.

Implantable cardioverter defibrillator therapy activation for high risk patients with relatively well preserved left ventricular ejection fraction. Does it really work?

Affiliations

Implantable cardioverter defibrillator therapy activation for high risk patients with relatively well preserved left ventricular ejection fraction. Does it really work?

Konstantinos A Gatzoulis et al. Int J Cardiol. .

Abstract

Background: Current guidelines for the primary prevention of sudden cardiac death have used a left ventricular ejection fraction (LVEF) ≤ 35% as a critical point to justify implantable cardioverter defibrillator (ICD) implantation in post myocardial infarction patients and in those with nonischemic dilated cardiomyopathy. We compared mortality and ICD activation rates among different ICD group recipients using a cut-off value for LVEF ≤ 35%.

Methods: We followed up for a mean period of 41.1 months 495 ICD recipients (442 males, 65.6 years old, 68.9% post myocardial infarction patients, 422 with LVEF ≤ 35%). Prevention was considered primary in patients who fulfilled guidelines criteria or had inducible ventricular arrhythmia during programmed ventricular stimulation for patients with LVEF >35%.

Results: Over the course of the trial, 84 of 495 patients died; 69 experienced cardiac death (6 sudden) and 15 non cardiac death. ICD recipients with LVEF ≤ 35% compared to those with preserved LVEF (mean LVEF=43%) had a greater incidence of total mortality (18% vs. 11%, log rank p=0.028) and cardiac death (15.4% vs. 5.5%, log rank p=0.005). There was no difference in the incidence for appropriate device therapy between patients with LVEF ≤ 35% and those with LVEF >35% (56.9% vs. 65.8%, log rank p=0.93). In the multivariate analysis the presence of advanced New York Heart Association stage predicted both total mortality (HR=2.69, 95% CI 1.771-4.086) and cardiac death (HR=3.437, 95% CI 2.163-5.463).

Conclusions: ICD therapy may protect heart failure patients at early stages from arrhythmic morbidity and mortality, based on an electrophysiology-guided risk stratification approach.

Keywords: Implantable cardioverter defibrillator; Left ventricular ejection fraction; Programmed ventricular stimulation.

PubMed Disclaimer

LinkOut - more resources