Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 May 21:727:8-12.
doi: 10.1016/j.aca.2012.03.022. Epub 2012 Apr 4.

An efficient extraction method for quantitation of adenosine triphosphate in mammalian tissues and cells

Affiliations

An efficient extraction method for quantitation of adenosine triphosphate in mammalian tissues and cells

Junji Chida et al. Anal Chim Acta. .

Abstract

Firefly bioluminescence is widely used in the measurement of adenosine 5'-triphosphate (ATP) levels in biological materials. For such assays in tissues and cells, ATP must be extracted away from protein in the initial step and extraction efficacy is the main determinant of the assay accuracy. Extraction reagents recommended in the commercially available ATP assay kits are chaotropic reagents, trichloroacetic acid (TCA), perchloric acid (PCA), and ethylene glycol (EG), which extract nucleotides through protein precipitation and/or nucleotidase inactivation. We found that these reagents are particularly useful for measuring ATP levels in materials with relatively low protein concentrations such as blood cells, cultured cells, and bacteria. However, these methods are not suitable for ATP extraction from tissues with high protein concentrations, because some ATP may be co-precipitated with the insolubilized protein during homogenization and extraction, and it could also be precipitated by neutralization in the acid extracts. Here we found that a phenol-based extraction method markedly increased the ATP and other nucleotides extracted from tissues. In addition, phenol extraction does not require neutralization before the luciferin-luciferase assay step. ATP levels analyzed by luciferase assay in various tissues extracted by Tris-EDTA-saturated phenol (phenol-TE) were over 17.8-fold higher than those extracted by TCA and over 550-fold higher than those in EG extracts. Here we report a simple, rapid, and reliable phenol-TE extraction procedure for ATP measurement in tissues and cells by luciferase assay.

PubMed Disclaimer

Publication types

LinkOut - more resources