Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Oct;108(1):186-96.
doi: 10.1016/j.cmpb.2012.03.004. Epub 2012 Apr 30.

An automated decision-support system for non-proliferative diabetic retinopathy disease based on MAs and HAs detection

Affiliations

An automated decision-support system for non-proliferative diabetic retinopathy disease based on MAs and HAs detection

Marwan D Saleh et al. Comput Methods Programs Biomed. 2012 Oct.

Abstract

Diabetic retinopathy (DR) has become a serious threat in our society, which causes 45% of the legal blindness in diabetes patients. Early detection as well as the periodic screening of DR helps in reducing the progress of this disease and in preventing the subsequent loss of visual capability. This paper provides an automated diagnosis system for DR integrated with a user-friendly interface. The grading of the severity level of DR is based on detecting and analyzing the early clinical signs associated with the disease, such as microaneurysms (MAs) and hemorrhages (HAs). The system extracts some retinal features, such as optic disc, fovea, and retinal tissue for easier segmentation of dark spot lesions in the fundus images. That is followed by the classification of the correctly segmented spots into MAs and HAs. Based on the number and location of MAs and HAs, the system quantifies the severity level of DR. A database of 98 color images is used in order to evaluate the performance of the developed system. From the experimental results, it is found that the proposed system achieves 84.31% and 87.53% values in terms of sensitivity for the detection of MAs and HAs respectively. In terms of specificity, the system achieves 93.63% and 95.08% values for the detection of MAs and HAs respectively. Also, the proposed system achieves 68.98% and 74.91% values in terms of kappa coefficient for the detection of MAs and HAs respectively. Moreover, the system yields sensitivity and specificity values of 89.47% and 95.65% for the classification of DR versus normal.

PubMed Disclaimer

LinkOut - more resources