Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors
- PMID: 2255233
- DOI: 10.1002/mrm.1910160111
Quantitation of blood-brain barrier defect by magnetic resonance imaging and gadolinium-DTPA in patients with multiple sclerosis and brain tumors
Abstract
In this study quantitation of the degree of deficiency of the blood-brain barrier (BBB) in patients with multiple sclerosis or brain tumors, by using MRI, is shown to be possible. As a measure of permeability of the BBB to Gadolinium-DTPA (Gd-DTPA) the flux per unit of distribution volume per unit of brain mass was used. This quantity was found by introducing the longitudinal relaxation rate (R1) as a measure of concentration of Gd-DTPA in the brain tissue in the mathematical model for the transcapillary transport over the BBB. High accordance between the observed data points and the model was found, and the results were comparable to results obtained from similar studies using positron emission tomography. The improved possibility of quantitating the defect of the BBB by MRI may give new information about pathogenesis or etiology, and leads to improved methods in monitoring the efficacy of treatments in intracranial diseases.
Similar articles
-
Measurement of blood-brain barrier permeability using dynamic Gd-DTPA scanning--a comparison of methods.Magn Reson Med. 1992 Mar;24(1):174-6. doi: 10.1002/mrm.1910240119. Magn Reson Med. 1992. PMID: 1556924
-
Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts.Magn Reson Med. 1991 Feb;17(2):357-67. doi: 10.1002/mrm.1910170208. Magn Reson Med. 1991. PMID: 2062210
-
Heterogeneity of blood-brain barrier changes in multiple sclerosis: an MRI study with gadolinium-DTPA enhancement.Neurology. 1990 Feb;40(2):229-35. doi: 10.1212/wnl.40.2.229. Neurology. 1990. PMID: 2300240
-
MR contrast enhancement of intracranial lesions with Gd-DTPA.Radiol Clin North Am. 1988 Jul;26(4):873-87. Radiol Clin North Am. 1988. PMID: 3289078 Review.
-
Modeling tracer kinetics in dynamic Gd-DTPA MR imaging.J Magn Reson Imaging. 1997 Jan-Feb;7(1):91-101. doi: 10.1002/jmri.1880070113. J Magn Reson Imaging. 1997. PMID: 9039598 Review.
Cited by
-
Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck.Quant Imaging Med Surg. 2012 Dec;2(4):245-53. doi: 10.3978/j.issn.2223-4292.2012.11.04. Quant Imaging Med Surg. 2012. PMID: 23289084 Free PMC article.
-
Optimal acquisition and modeling parameters for accurate assessment of low Ktrans blood-brain barrier permeability using dynamic contrast-enhanced MRI.Magn Reson Med. 2016 May;75(5):1967-77. doi: 10.1002/mrm.25793. Epub 2015 Jun 16. Magn Reson Med. 2016. PMID: 26077645 Free PMC article.
-
Effect of breathing a hyperoxic hypercapnic gas mixture on the oxygenation of meningiomas; preliminary results.J Neurooncol. 2002 Apr;57(2):127-32. doi: 10.1023/a:1015732909712. J Neurooncol. 2002. PMID: 12125973
-
Effects of flip angle uncertainty and noise on the accuracy of DCE-MRI metrics: comparison between standard concentration-based and signal difference methods.Magn Reson Imaging. 2015 Jan;33(1):166-73. doi: 10.1016/j.mri.2014.10.005. Epub 2014 Oct 13. Magn Reson Imaging. 2015. PMID: 25311569 Free PMC article.
-
Optimization of Look-Locker Turbo-Field Echo-Planar Imaging and Evaluation of Its Accuracy in Head and Neck 3D T1 Mapping.Magn Reson Med Sci. 2016 Jul 11;15(3):288-98. doi: 10.2463/mrms.mp.2015-0057. Epub 2015 Dec 28. Magn Reson Med Sci. 2016. PMID: 26726016 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical