Magnetic susceptibility shift selected imaging: MESSI
- PMID: 2255239
- DOI: 10.1002/mrm.1910160109
Magnetic susceptibility shift selected imaging: MESSI
Abstract
Paramagnetic compounds are often used to enhance contrast in MRI by virtue of their increase in the kinetics of the relaxation of water 1H magnetization. Here, we demonstrate a method for contrast enhancement which is based on the resonance frequency shifts caused by the bulk magnetic susceptibility (BMS) effects of such compounds. This involves the frequency selective excitation in the absence of field gradients, during the imaging sequence, of a portion of the water 1H resonance which is rendered inhomogeneous by BMS shifts only. The image which results is of that portion of the sample which gives rise to the portion of the spectrum excited. A phantom sample which simulates some aspects of tissue, particularly blood vessels with different orientations in the magnetic field, was prepared. The contrast enhancement exhibited here avoids some of the distortions attendant to the use of paramagnetic reagents. This new approach can, in principle, utilize the natural BMS differences found in all tissue.
Similar articles
-
Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.Magn Reson Med. 1990 Oct;16(1):9-18. doi: 10.1002/mrm.1910160103. Magn Reson Med. 1990. PMID: 2255240
-
Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: use of paramagnetic reagents.Magn Reson Med. 1990 Feb;13(2):239-62. doi: 10.1002/mrm.1910130207. Magn Reson Med. 1990. PMID: 2156125
-
Improved MR imaging in extremely inhomogeneous radio-frequency fields.Magn Reson Imaging. 1991;9(1):61-5. doi: 10.1016/0730-725x(91)90097-6. Magn Reson Imaging. 1991. PMID: 2056852
-
SQUID-detected magnetic resonance imaging in microtesla fields.Annu Rev Biomed Eng. 2007;9:389-413. doi: 10.1146/annurev.bioeng.9.060906.152010. Annu Rev Biomed Eng. 2007. PMID: 17328671 Review.
-
Magnetic resonance angiography techniques.Invest Radiol. 1992 Dec;27 Suppl 2:S27-32. doi: 10.1097/00004424-199212002-00006. Invest Radiol. 1992. PMID: 1468872 Review.
Cited by
-
pCEST: Positive contrast using Chemical Exchange Saturation Transfer.J Magn Reson. 2012 Feb;215:64-73. doi: 10.1016/j.jmr.2011.12.011. Epub 2011 Dec 27. J Magn Reson. 2012. PMID: 22237630 Free PMC article.
-
MR susceptibility imaging.J Magn Reson. 2013 Apr;229:198-207. doi: 10.1016/j.jmr.2012.11.013. Epub 2012 Nov 29. J Magn Reson. 2013. PMID: 23273840 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical