Velocity-selective (VS) arterial spin labeling is a promising method for measuring perfusion in areas of slow or collateral flow by eliminating the bolus arrival delay associated with other spin labeling techniques. However, B(0) and B(1) inhomogeneities and eddy currents during the VS preparation hinder accurate quantification of perfusion with VS arterial spin labeling. In this study, it is demonstrated through simulations and experiments in healthy volunteers that eddy currents cause erroneous tagging of static tissue. Consequently, mean gray matter perfusion is overestimated by up to a factor of 2, depending on the VS preparation used. A novel eight-segment B(1) insensitive rotation VS preparation is proposed to reduce eddy current effects while maintaining the B(0) and B(1) insensitivity of previous preparations. Compared to two previous VS preparations, the eight-segment B(1) insensitive rotation is the most robust to eddy currents and should improve the quality and reliability of VS arterial spin labeling measurements in future studies.
Copyright © 2012 Wiley Periodicals, Inc.
Similar articles
-
An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.Magn Reson Med. 2015 Mar;73(3):1085-94. doi: 10.1002/mrm.25227. Epub 2014 Apr 7. Magn Reson Med. 2015. PMID: 24710761
-
Perfusion quantification by model-free arterial spin labeling using nonlinear stochastic regularization deconvolution.Magn Reson Med. 2013 Nov;70(5):1470-80. doi: 10.1002/mrm.24587. Epub 2012 Dec 27. Magn Reson Med. 2013. PMID: 23281031
-
Efficient sampling of early signal arrival for estimation of perfusion and transit time in whole-brain arterial spin labeling.Magn Reson Med. 2012 Jul;68(1):179-87. doi: 10.1002/mrm.23222. Epub 2011 Dec 21. Magn Reson Med. 2012. PMID: 22189961
-
Brain perfusion territory imaging: methods and clinical applications of selective arterial spin-labeling MR imaging.Radiology. 2008 Feb;246(2):354-64. doi: 10.1148/radiol.2462061775. Radiology. 2008. PMID: 18227536 Review.
-
Perfusion imaging.J Magn Reson Imaging. 2014 Aug;40(2):269-79. doi: 10.1002/jmri.24382. Epub 2013 Nov 25. J Magn Reson Imaging. 2014. PMID: 24988916 Review.
Cited by
-
Velocity-selective-inversion prepared arterial spin labeling.Magn Reson Med. 2016 Oct;76(4):1136-48. doi: 10.1002/mrm.26010. Epub 2015 Oct 28. Magn Reson Med. 2016. PMID: 26507471 Free PMC article.
-
Multi-organ comparison of flow-based arterial spin labeling techniques: Spatially non-selective labeling for cerebral and renal perfusion imaging.Magn Reson Med. 2021 May;85(5):2580-2594. doi: 10.1002/mrm.28603. Epub 2020 Nov 30. Magn Reson Med. 2021. PMID: 33251644 Free PMC article.
-
Diffusion-prepared fast spin echo for artifact-free spinal cord imaging.Magn Reson Med. 2021 Aug;86(2):984-994. doi: 10.1002/mrm.28751. Epub 2021 Mar 15. Magn Reson Med. 2021. PMID: 33720450 Free PMC article.
-
Robust dual-module velocity-selective arterial spin labeling (dm-VSASL) with velocity-selective saturation and inversion.Magn Reson Med. 2023 Mar;89(3):1026-1040. doi: 10.1002/mrm.29513. Epub 2022 Nov 6. Magn Reson Med. 2023. PMID: 36336852 Free PMC article.
-
Systematic evaluation of velocity-selective arterial spin labeling settings for placental perfusion measurement.Magn Reson Med. 2020 Oct;84(4):1828-1843. doi: 10.1002/mrm.28240. Epub 2020 Mar 6. Magn Reson Med. 2020. PMID: 32141655 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources