Influence of indoor climate on the sick building syndrome in an office environment. The Danish Indoor Climate Study Group
Abstract
The influence of indoor climate factors on symptoms of the sick building syndrome was investigated in Greater Copenhagen, Denmark. Altogether, 2369 office workers in 14 buildings, where indoor climate measurements were made, filled out a questionnaire. Multivariate logistic regression analyses of the multifactorial effects on the prevalence of work-related mucosal irritation and work-related general symptoms among the office workers showed that the concentration of macromolecular organic floor dust, the floor covering, the number of workplaces in the office, the age of the building, the type of ventilation, and two easily recognizable factors, the shelf factor and the fleece factor, were associated with the prevalence of symptoms.
Similar articles
-
Influence of personal characteristics, job-related factors and psychosocial factors on the sick building syndrome. Danish Indoor Climate Study Group.Scand J Work Environ Health. 1989 Aug;15(4):286-95. doi: 10.5271/sjweh.1851. Scand J Work Environ Health. 1989. PMID: 2772583
-
Symptoms prevalence among office workers of a sealed versus a non-sealed building: associations to indoor air quality.Environ Int. 2009 Nov;35(8):1136-41. doi: 10.1016/j.envint.2009.07.005. Epub 2009 Aug 8. Environ Int. 2009. PMID: 19665795
-
Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds.Int J Environ Res Public Health. 2015 May 27;12(6):5833-45. doi: 10.3390/ijerph120605833. Int J Environ Res Public Health. 2015. PMID: 26024357 Free PMC article.
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
-
Sick building syndrome: acute illness among office workers--the role of building ventilation, airborne contaminants and work stress.Allergy Proc. 1990 May-Jun;11(3):109-16. doi: 10.2500/108854190778880268. Allergy Proc. 1990. PMID: 2196201 Review.
Cited by
-
Ventilation rate in office buildings and sick building syndrome.Occup Environ Med. 1995 Nov;52(11):709-14. doi: 10.1136/oem.52.11.709. Occup Environ Med. 1995. PMID: 8535489 Free PMC article.
-
Respiratory health among Korean pupils in relation to home, school and outdoor environment.J Korean Med Sci. 2011 Feb;26(2):166-73. doi: 10.3346/jkms.2011.26.2.166. Epub 2011 Jan 24. J Korean Med Sci. 2011. PMID: 21286005 Free PMC article.
-
Interior surface materials in the home and the development of bronchial obstruction in young children in Oslo, Norway.Am J Public Health. 1999 Feb;89(2):188-92. doi: 10.2105/ajph.89.2.188. Am J Public Health. 1999. PMID: 9949747 Free PMC article.
-
Effects of green buildings on employee health and productivity.Am J Public Health. 2010 Sep;100(9):1665-8. doi: 10.2105/AJPH.2009.180687. Epub 2010 Jul 15. Am J Public Health. 2010. PMID: 20634460 Free PMC article.
-
Occupant health in buildings: Impact of the COVID-19 pandemic on the opinions of building professionals and implications on research.Build Environ. 2022 Jan;207:108440. doi: 10.1016/j.buildenv.2021.108440. Epub 2021 Oct 16. Build Environ. 2022. PMID: 34697517 Free PMC article.