. 2012 Nov;42(5):851-6; discussion 856-7.
doi: 10.1093/ejcts/ezs157. Epub 2012 May 4.

Descending aortic aneurysmal changes following surgery for acute DeBakey type I aortic dissection

Affiliations

Descending aortic aneurysmal changes following surgery for acute DeBakey type I aortic dissection

Joon Bum Kim et al. Eur J Cardiothorac Surg. 2012 Nov.

Abstract

Objective: The aim of the study was to determine the risk factors for descending aortic aneurysmal changes following surgery for acute DeBakey type I aortic dissection.

Methods: A total of 129 patients who underwent surgery for acute type I aortic dissection between 2000 and 2010 were evaluated by contrast-enhanced computed tomography (CT) at least 6 months later (median follow-up 29.5 months, interquartile range 16.3-49.3 months). The study endpoint was the development of aortic aneurysms (diameter >55 mm). Risk factors for aortic aneurysms were determined by Cox regression analysis.

Results: Aortic dilatation occurred in 23 of the 129 (17.8%) patients. Aortic aneurysms were observed at the proximal descending in 19 (14.7%) patients, the mid descending in 12 (9.3%) patients, the distal descending in seven (5.4%) patients and at the abdominal aorta in one (0.8%) patient. Multivariate analysis showed that the luminal diameter of the proximal descending aorta on initial CT was the only significant and independent factor predicting aneurysm formation (hazard ratio 1.12, 95% confidence interval [CI] 1.02-1.22, P = 0.014). Receiver operating curves assessing the ability of preoperative proximal descending aorta diameter to predict aortic aneurysms showed an area under the curve of 0.72 (95% CI 0.60-0.84, P = 0.001), with a greatest accuracy at 40.95 mm (sensitivity 65.2%, specificity 78.3%). The 5-year freedom from aortic aneurysm rates in patients with proximal descending diameters ≤ 40 and >40 mm were 84.4 ± 6.6 and 55.6 ± 11.1%, respectively (P = 0.001).

Conclusions: The proximal descending aorta was the major site of aneurysm formation following surgery for acute type I aortic dissection. The large proximal descending aortic diameter on initial CT predicted the late aneurysm, suggesting that adjunctive procedures combined with aortic replacement are needed to prevent the late aneurysm.

PubMed Disclaimer

Comment in

Publication types

MeSH terms