Hyperthermia-triggered drug delivery from temperature-sensitive liposomes using MRI-guided high intensity focused ultrasound
- PMID: 22565055
- DOI: 10.1016/j.jconrel.2012.04.041
Hyperthermia-triggered drug delivery from temperature-sensitive liposomes using MRI-guided high intensity focused ultrasound
Abstract
In the continuous search for cancer therapies with a higher therapeutic window, localized temperature-induced drug delivery may offer a minimal invasive treatment option. Here, a chemotherapeutic drug is encapsulated into a temperature-sensitive liposome (TSL) that is released at elevated temperatures, for example, when passing through a locally heated tumor. Consequently, high drug levels in the tumor tissue can be achieved, while reducing drug exposure to healthy tissue. Although the concept of temperature-triggered drug delivery was suggested more than thirty years ago, several chemical and technological challenges had to be addressed to advance this approach towards clinical translation. In particular, non-invasive focal heating of tissue in a controlled fashion remained a challenge. For the latter, high intensity focused ultrasound (HIFU) allows non-invasive heating to establish hyperthermia (40-45 °C) of tumor tissue over time. Magnetic resonance imaging (MRI) plays a pivotal role in this procedure thanks to its superb spatial resolution for soft tissue as well as the possibility to acquire 3D temperature information. Consequently, MRI systems emerged with an HIFU ultrasound transducer embedded in the patient bed (MR-HIFU), where the MRI is utilized for treatment planning, and to provide spatial and temperature feedback to the HIFU. For tumor treatment, the lesion is heated to 42 °C using HIFU. At this temperature, the drug-loaded TSLs release their payload in a quantitative fashion. The concept of temperature-triggered drug delivery has been extended to MR image-guided drug delivery by the co-encapsulation of a paramagnetic MRI contrast agent in the lumen of TSLs. This review will give an overview of recent developments in temperature-induced drug delivery using HIFU under MRI guidance.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Magnetic resonance guided high-intensity focused ultrasound for image-guided temperature-induced drug delivery.Adv Drug Deliv Rev. 2014 Jun;72:65-81. doi: 10.1016/j.addr.2014.01.006. Epub 2014 Jan 22. Adv Drug Deliv Rev. 2014. PMID: 24463345 Review.
-
Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.Invest Radiol. 2017 Oct;52(10):620-630. doi: 10.1097/RLI.0000000000000392. Invest Radiol. 2017. PMID: 28598900
-
A novel approach to identify non-palpable breast lesions combining fluorescent liposomes and magnetic resonance-guided high intensity focused ultrasound-triggered release.Eur J Pharm Biopharm. 2011 Apr;77(3):458-64. doi: 10.1016/j.ejpb.2010.12.028. Epub 2010 Dec 31. Eur J Pharm Biopharm. 2011. PMID: 21195760
-
Thermal combination therapies for local drug delivery by magnetic resonance-guided high-intensity focused ultrasound.Proc Natl Acad Sci U S A. 2017 Jun 13;114(24):E4802-E4811. doi: 10.1073/pnas.1700790114. Epub 2017 May 31. Proc Natl Acad Sci U S A. 2017. PMID: 28566498 Free PMC article.
-
Spatio-temporal control of gene expression and cancer treatment using magnetic resonance imaging-guided focused ultrasound.Clin Cancer Res. 2007 Jun 15;13(12):3482-9. doi: 10.1158/1078-0432.CCR-07-0204. Clin Cancer Res. 2007. PMID: 17575210 Review.
Cited by
-
Hyperthermia as adjunct to intravesical chemotherapy for bladder cancer.Biomed Res Int. 2013;2013:262313. doi: 10.1155/2013/262313. Epub 2013 Sep 1. Biomed Res Int. 2013. PMID: 24073396 Free PMC article. Review.
-
Temperature sensitive liposomes combined with thermal ablation: Effects of duration and timing of heating in mathematical models and in vivo.PLoS One. 2017 Jun 12;12(6):e0179131. doi: 10.1371/journal.pone.0179131. eCollection 2017. PLoS One. 2017. PMID: 28604815 Free PMC article.
-
Sequential HIFU heating and nanobubble encapsulation provide efficient drug penetration from stealth and temperature sensitive liposomes in colon cancer.J Control Release. 2017 Feb 10;247:55-63. doi: 10.1016/j.jconrel.2016.12.033. Epub 2016 Dec 30. J Control Release. 2017. PMID: 28042085 Free PMC article.
-
The Correction of Focal Point Displacement Caused by the Refraction of the Beams in High-Intensity Focused Ultrasound.J Med Signals Sens. 2017 Jul-Sep;7(3):178-184. J Med Signals Sens. 2017. PMID: 28840119 Free PMC article.
-
Ultrasound-based triggered drug delivery to tumors.Drug Deliv Transl Res. 2018 Feb;8(1):150-164. doi: 10.1007/s13346-017-0448-6. Drug Deliv Transl Res. 2018. PMID: 29204925 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources