Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Oct;11(5):415-20.
doi: 10.7785/tcrt.2012.500262. Epub 2012 May 7.

Radiation therapy for nasopharyngeal carcinoma using simultaneously integrated boost (SIB) protocol: a comparison planning study between intensity modulated arc radiotherapy vs. intensity modulated radiotherapy

Affiliations
Free article
Comparative Study

Radiation therapy for nasopharyngeal carcinoma using simultaneously integrated boost (SIB) protocol: a comparison planning study between intensity modulated arc radiotherapy vs. intensity modulated radiotherapy

Tonghai Liu et al. Technol Cancer Res Treat. 2012 Oct.
Free article

Abstract

The aim of this paper is to compare the dosimetric difference between intensity-modulated arc therapy (IMAT) and conventional intensity-modulated radiation therapy (IMRT) for radiotherapy of nasopharyngeal carcinoma (NPC) using simultaneously integrated boost (SIB) protocol. Ten patients with nasopharyngeal carcinoma underwent SIB protocol were retrospectively studied. The plan target volume (PTV) of NPC contained nasopharynx gross target volume and the positive neck lymph nodes, PTV1 contained the high-risk sites of microscopic extension and the whole nasopharynx and PTV2 contained the low-risk sites. The prescription dose of PTV was 66 Gy/30 fractions, and for PTV1 60 Gy/30 fractions and for PTV2 54 Gy/30 fractions. IMAT (two 358° arcs) and IMRT (7 fields) plans were designed for each patients using SIB strategies. The monitor unit (MU), treatment time (T) and dosimetric difference between IMRT and IMAT were compared. IMAT can achieve better conformal index (CI) than IMRT (P < 0.05) for all PTVs, while no significant difference were found in homogeneity index (HI) (P > 0.05). There's no significant difference found in radiation dose of brain stem, lenses and parotids, while the maximum dose of spinal cord of IMAT was higher than IMRT (P < 0.05). The monitor unit of IMRT (1308 ± 213) was more than IMAT (606 ± 96) (P < 0.05), while the treatment time of IMRT (540 ± 160S) was more than IMAT (160 ± 10S). This study shows that IMAT using SIB strategies for NPC radiotherapy can achieve similar target coverage with better conformity with less MU and delivery time comparing to IMRT.

PubMed Disclaimer

Publication types

LinkOut - more resources