Radiochromatography in pharmaceutical and biomedical analysis
- PMID: 2258416
- DOI: 10.1016/s0378-4347(00)82282-3
Radiochromatography in pharmaceutical and biomedical analysis
Abstract
Recent advances in the chromatographic analysis of radiolabelled compounds are discussed, with emphasis on the optimization of radioactivity detection in modern chromatographic techniques. Applications are mentioned only infrequently. The state-of-the-art of common radioactivity detection methods is reviewed, as well as promising new detection principles. The latter include flow-through liquid scintillation counting of reversed-phase column eluates based on post-column extraction and solvent segmentation, flow-through heterogeneous counting using a flow cell constructed from axially aligned scintillation fibres, flow cells especially constructed for the detection of beta-emitting radioisotopes in capillary zone electrophoresis, position-sensitive analysers employed in radio planar chromatography and, finally 14C atom counting (as opposed to 14C decay counting) by accelerator mass spectrometry.
Similar articles
-
A microplate solid scintillation counter as a radioactivity detector for high performance liquid chromatography in drug metabolism: validation and applications.J Chromatogr A. 2006 Nov 10;1133(1-2):184-94. doi: 10.1016/j.chroma.2006.08.020. Epub 2006 Sep 12. J Chromatogr A. 2006. PMID: 16970958
-
Cytostar-T plates--a valid alternative for microplate scintillation counting of low radioactivity in combination with high-performance liquid chromatography in drug metabolism studies?J Chromatogr A. 2007 Jul 20;1157(1-2):65-72. doi: 10.1016/j.chroma.2007.04.016. Epub 2007 Apr 19. J Chromatogr A. 2007. PMID: 17466316
-
Radio high-performance liquid chromatographic determination of 14C-labelled LF 2-0254, A 1,4-dihydropyridine calcium antagonist, in rat and dog plasma using off-line liquid scintillation counting.J Chromatogr. 1988 Dec 2;456(1):183-90. doi: 10.1016/0021-9673(86)80017-6. J Chromatogr. 1988. PMID: 3243866
-
Immunoaffinity solid-phase extraction for pharmaceutical and biomedical trace-analysis-coupling with HPLC and CE-perspectives.J Pharm Biomed Anal. 2004 Mar 1;34(4):717-36. doi: 10.1016/S0731-7085(03)00559-4. J Pharm Biomed Anal. 2004. PMID: 15019051 Review.
-
Chemiluminescence detection in HPLC and CE for pharmaceutical and biomedical analysis.Biomed Chromatogr. 2003 Mar-Apr;17(2-3):96-105. doi: 10.1002/bmc.238. Biomed Chromatogr. 2003. PMID: 12717797 Review.
Cited by
-
A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.J Radioanal Nucl Chem. 2017;313(1):217-227. doi: 10.1007/s10967-017-5282-2. Epub 2017 May 22. J Radioanal Nucl Chem. 2017. PMID: 28680190 Free PMC article.
-
Accelerator mass spectrometry-enabled studies: current status and future prospects.Bioanalysis. 2010 Mar;2(3):519-41. doi: 10.4155/bio.09.188. Bioanalysis. 2010. PMID: 20440378 Free PMC article. Review.
-
Metabolite profiles of two [14C]-labelled catechol O-methyltransferase inhibitors, nitecapone and entacapone, in rat and mouse urine and rat bile.Eur J Drug Metab Pharmacokinet. 1994 Apr-Jun;19(2):125-35. doi: 10.1007/BF03188833. Eur J Drug Metab Pharmacokinet. 1994. PMID: 8001593
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical