Preconcentration of trace amounts of methadone in human urine, plasma, saliva and sweat samples using dispersive liquid-liquid microextraction followed by high performance liquid chromatography
- PMID: 22608423
- DOI: 10.1016/j.talanta.2012.03.004
Preconcentration of trace amounts of methadone in human urine, plasma, saliva and sweat samples using dispersive liquid-liquid microextraction followed by high performance liquid chromatography
Abstract
A simple, rapid and efficient method for the preconcentration of methadone was developed using dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with ultra violet detection (HPLC-UV). The extraction method is based on the fast injection of a mixture of extracting and disperser solvents into the aqueous solution to form a cloudy ternary component solvent (aqueous solution:extracting solvent:disperser solvent) system. The extraction parameters such as nature and volume of extracting and disperser solvents, pH of sample, and extraction time were studied for optimization. Under the optimal conditions (extracting solvent: chloroform, 250 μL; disperser solvent: methanol, 2.5 mL and pH of sample: 10.0) a linear calibration curve was obtained in the range of 0.5-5000 ng mL(-1) with r(2)=0.9995. To demonstrate analytical performance, figures of merits of the proposed method in four different biological matrices (urine, plasma, saliva and sweat) spiked with methadone were investigated. The limits of detection and quantification in these matrices were ranged from 4.90 to 24.85 ng mL(-1) and 16.32 to 82.75 ng mL(-1), respectively. The extraction recoveries were above 97% and the preconcentration factors of methadone in distilled water, urine, plasma, saliva, and sweat samples were 196.52, 10.03, 9.93, 1.97 and 1.99, respectively. While the precision for inter-day was ≤6.43 (n=5), it was ≤2.26 (n=5) for intra-day assay. Finally, the method was successfully applied in the determination of methadone in the human urine, plasma, saliva and sweat samples.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Utilization of inverted dispersive liquid-liquid microextraction followed by HPLC-UV as a sensitive and efficient method for the extraction and determination of quercetin in honey and biological samples.Talanta. 2012 Jan 30;89:117-23. doi: 10.1016/j.talanta.2011.11.079. Epub 2011 Dec 4. Talanta. 2012. PMID: 22284468
-
A novel method for high preconcentration of ultra trace amounts of B₁, B₂, G₁ and G₂ aflatoxins in edible oils by dispersive liquid-liquid microextraction after immunoaffinity column clean-up.J Chromatogr A. 2012 Jul 20;1247:35-41. doi: 10.1016/j.chroma.2012.05.051. Epub 2012 May 22. J Chromatogr A. 2012. PMID: 22673813
-
Low-density solvent-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of warfarin in human plasma.J Chromatogr B Analyt Technol Biomed Life Sci. 2012 Jun 15;899:66-71. doi: 10.1016/j.jchromb.2012.04.035. Epub 2012 May 6. J Chromatogr B Analyt Technol Biomed Life Sci. 2012. PMID: 22622064
-
Dispersive liquid-liquid microextraction: trends in the analysis of biological samples.Bioanalysis. 2015;7(17):2211-25. doi: 10.4155/bio.15.141. Epub 2015 Sep 23. Bioanalysis. 2015. PMID: 26395171 Review.
-
Recent developments in dispersive liquid-liquid microextraction.Anal Bioanal Chem. 2014 Mar;406(8):2027-66. doi: 10.1007/s00216-013-7467-z. Epub 2013 Nov 21. Anal Bioanal Chem. 2014. PMID: 24258401 Review.
Cited by
-
Application of Microextraction-Based Techniques for Screening-Controlled Drugs in Forensic Context-A Review.Molecules. 2021 Apr 9;26(8):2168. doi: 10.3390/molecules26082168. Molecules. 2021. PMID: 33918766 Free PMC article. Review.
-
Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry.J Anal Methods Chem. 2016;2016:5976324. doi: 10.1155/2016/5976324. Epub 2016 Oct 17. J Anal Methods Chem. 2016. PMID: 27830105 Free PMC article.
-
Applicability of a green nanocomposite consists of reduced graphene oxide and β-cyclodextrin for electrochemical tracing of methadone in human biofluids validated by international greenness indexes.Heliyon. 2024 Nov 19;10(23):e40505. doi: 10.1016/j.heliyon.2024.e40505. eCollection 2024 Dec 15. Heliyon. 2024. PMID: 39669158 Free PMC article.
-
Validation and Optimization of Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction as a Preparation Method for Detection of Methadone in Saliva with Gas Chromatography-Mass Spectrometry Technique.Adv Pharm Bull. 2020 Jun;10(2):329-333. doi: 10.34172/apb.2020.040. Epub 2020 Feb 18. Adv Pharm Bull. 2020. PMID: 32373504 Free PMC article.
-
Determination and Validation of a Solid-phase Extraction Gas Chromatography-mass Spectrometry for the Quantification of Methadone and Its Principal Metabolite in Human Plasma.Anal Chem Insights. 2015 Aug 26;10:17-22. doi: 10.4137/ACI.S25554. eCollection 2015. Anal Chem Insights. 2015. PMID: 26339186 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical