Comprehensive analysis of cardiac arrhythmias in telemetered cynomolgus monkeys over a 6 month period
- PMID: 22613062
- DOI: 10.1016/j.vascn.2012.05.002
Comprehensive analysis of cardiac arrhythmias in telemetered cynomolgus monkeys over a 6 month period
Abstract
Introduction: Cardiac arrhythmia findings can be a challenge to interpret and difficult to attribute to background incidence or test article treatment. Thus, there is a growing need to better understand arrhythmia incidence in the experimental animal models used to assess the cardiovascular safety of new drugs. Currently, there is little information on the frequency of spontaneous cardiac arrhythmias in the cynomolgus monkey.
Methods: This study evaluated the baseline arrhythmia rate in a group (n=19) of non-naïve (drug-free) male telemetered cynomolgus monkeys at various timepoints over a 6 month period. When sampled, data were collected continuously (24 hour bins over a 6 month period) and the ECG waveforms analyzed for arrhythmia using a semi-automated approach with pattern recognition software. The arrhythmia data were evaluated to detect atrial and ventricular patterns, as well as changes associated with circadian rhythm.
Results: Evaluation of this data showed that cynomolgus monkeys can exhibit spontaneous arrhythmias (day cycle; means) of the following types: supraventricular premature contraction (SPC, 10.7%); escape beats (EB, 3.8%); and sinus node pause (SNP, 2.8%), with others below 2%. From the ventricular perspective, ventricular premature beats (VPB, 25.4% (day cycle mean)) were the most prevalent. Circadian analysis indicated that some arrhythmias had higher incidence during the night cycle: SNP (32.6%); EB (18.5%); atrioventricular block (AVB, 2.7%), an indication that the arrhythmia pattern is influenced by the diurnal cycle.
Discussion: Overall, the data demonstrated that a variety of spontaneous arrhythmias occur at low frequency in non-treated animals, and the incidence varies between animals, and within the same animal when repeatedly sampled. Given the low incidence in normal animals, continuous ECG sampling over multiple days is needed to establish an accurate arrhythmia "fingerprint" for each animal in dedicated telemetry colonies, which could assist the interpretation of arrhythmia findings that may occur in cardiovascular safety studies.
Copyright © 2012 Elsevier Inc. All rights reserved.
Similar articles
-
Effects of telemetric epicardial leads and ventricular catheters on arrhythmia incidence in cynomolgus monkeys.J Pharmacol Toxicol Methods. 2014 Mar-Apr;69(2):167-76. doi: 10.1016/j.vascn.2013.11.001. Epub 2013 Nov 18. J Pharmacol Toxicol Methods. 2014. PMID: 24262389
-
Quickly finding a needle in a haystack: a new automated cardiac arrhythmia detection software for preclinical studies.J Pharmacol Toxicol Methods. 2012 Sep;66(2):92-7. doi: 10.1016/j.vascn.2012.04.008. Epub 2012 Apr 23. J Pharmacol Toxicol Methods. 2012. PMID: 22554864
-
ECG arrhythmias in non-implanted vs. telemetry-implanted dogs: need for screening before and sufficient recovery time after implantation.J Pharmacol Toxicol Methods. 2011 Jul-Aug;64(1):60-7. doi: 10.1016/j.vascn.2011.04.001. Epub 2011 Apr 9. J Pharmacol Toxicol Methods. 2011. PMID: 21501690
-
Contribution of atrial pacing to understanding of the genesis of arrhythmias.Cardiovasc Clin. 1974;6(1):25-42. Cardiovasc Clin. 1974. PMID: 4140027 Review. No abstract available.
-
Intraoperative management of critical arrhythmia.Korean J Anesthesiol. 2017 Apr;70(2):120-126. doi: 10.4097/kjae.2017.70.2.120. Epub 2017 Feb 21. Korean J Anesthesiol. 2017. PMID: 28367281 Free PMC article. Review.
Cited by
-
The effect of aging on the specialized conducting system: a telemetry ECG study in rats over a 6 month period.PLoS One. 2014 Nov 14;9(11):e112697. doi: 10.1371/journal.pone.0112697. eCollection 2014. PLoS One. 2014. PMID: 25398004 Free PMC article.
-
Using imaging photoplethysmography for heart rate estimation in non-human primates.PLoS One. 2018 Aug 31;13(8):e0202581. doi: 10.1371/journal.pone.0202581. eCollection 2018. PLoS One. 2018. PMID: 30169537 Free PMC article.
-
Automated video-based heart rate tracking for the anesthetized and behaving monkey.Sci Rep. 2020 Oct 21;10(1):17940. doi: 10.1038/s41598-020-74954-5. Sci Rep. 2020. PMID: 33087832 Free PMC article.