Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Dec;57(12):2026-31.
doi: 10.4187/respcare.01527.

Intra-individual variation of the cuff-leak test as a predictor of post-extubation stridor

Affiliations

Intra-individual variation of the cuff-leak test as a predictor of post-extubation stridor

Antoine Gros et al. Respir Care. 2012 Dec.

Abstract

Background: This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor.

Methods: Prospective, clinical investigation in the ICU of a non-university hospital. CLTs were performed immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak (ΔCLT = CL(T1) - CL(T0)).

Results: We included 104 mechanically ventilated subjects in the study over a 12-month period. The incidence of post-extubation stridor was 6.7%. Stridor was more common in females of short stature. ΔCLT was considered as significant when CL(T1) - CL(T0) was negative. The sensitivity and the specificity of the test were 86% and 48%, respectively. When we tested the pre-extubation CLT alone with a threshold of 130 mL as a predictor of post-extubation stridor, the sensitivity and the specificity of the test were 86% and 76%, respectively.

Conclusions: The intra-individual variation of CLT immediately post-intubation and pre-extubation does not improve the accuracy of a standard pre-extubation CLT to predict post-extubation stridor. Moreover, the standard pre-extubation CLT did not appear in our study to be an ideal test to detect post-extubation stridor. Larger studies should be performed before generalizing these preliminary results.