Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jun 26;125(25):3133-41.
doi: 10.1161/CIRCULATIONAHA.111.090266. Epub 2012 May 21.

Long-term outcome of aortic dissection with patent false lumen: predictive role of entry tear size and location

Affiliations
Free article

Long-term outcome of aortic dissection with patent false lumen: predictive role of entry tear size and location

Artur Evangelista et al. Circulation. .
Free article

Abstract

Background: Patent false lumen in aortic dissection has been associated with poor prognosis. We aimed to assess the natural evolution of this condition and predictive factors.

Methods and results: One hundred eighty-four consecutive patients, 108 surgically treated type A and 76 medically treated type B, were discharged after an acute aortic dissection with patent false lumen. Transesophageal echocardiography was performed before discharge, and computed tomography was performed at 3 months and yearly thereafter. Median follow-up was 6.42 years (quartile 1 to quartile 3: 3.31-10.49). Forty-nine patients died during follow-up (22 type A, 27 type B), 31 suddenly. Surgical or endovascular treatment was indicated in 10 type A and 25 type B cases. Survival free from sudden death and surgical-endovascular treatment was 0.90, 0.81, and 0.46 (95% CI, 0.36-0.55) at 3, 5, and 10 years, respectively. Multivariate analysis identified baseline maximum descending aorta diameter (hazard ratio [HR]: 1.32 [1.10-1.59]; P=0.003), proximal location (HR: 1.84 [1.06-3.19]; P=0.03), and entry tear size (HR: 1.13 [1.08-1.2]; P<0.001) as predictors of dissection-related adverse events, whereas mortality was predicted by baseline maximum descending aorta diameter (HR: 1.36 [1.08-1.70]; P=0.008), entry tear size (HR: 1.1 [1.04-1.16]; P=0.001), and Marfan syndrome (HR: 3.66 [1.65-8.13]; P=0.001).

Conclusions: Aortic dissection with persistent patent false lumen carries a high risk of complications. In addition to Marfan syndrome and aorta diameter, a large entry tear located in the proximal part of the dissection identifies a high-risk subgroup of patients who may benefit from earlier and more aggressive therapy.

PubMed Disclaimer

Publication types