The downside of right ventricular apical pacing

Affiliations

The downside of right ventricular apical pacing

Andrew Brenyo et al. Indian Pacing Electrophysiol J. 2012 May.

Abstract

The right ventricular (RV) apex has been the standard pacing site since the development of implantable pacemaker technology. Although RV pacing was initially only utilized for the treatment of severe bradyarrhythmias usually due to complete heart block, today the indications for and implantation of RV pacing devices is dramatically larger. Recently, the adverse effects of chronic RV apical pacing have been described including an increased risk of heart failure and death. This review details the detrimental effects of RV apical pacing and their shared hemodynamic pathophysiology. In particular, the role of RV apical pacing induced ventricular dyssynchrony is highlighted with a specific focus on differential outcome based upon QRS morphology at implant.

Keywords: down side; right ventricular pacing.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Probability of long-term mortality by percent of right ventricular pacing and ICD implantation in the MADIT II trial with extended follow up. (reproduced with permission of the publisher [9])
Figure 2
Figure 2
Probability of long-term mortality by percent of right ventricular pacing in patients with LBBB (A) and without LBBB (B) in the MADIT II trial with extended follow up. (reproduced with permission of the publisher [9])
Figure 2
Figure 2
Probability of long-term mortality by percent of right ventricular pacing in patients with LBBB (A) and without LBBB (B) in the MADIT II trial with extended follow up. (reproduced with permission of the publisher [9])

References

    1. Zoll PM, et al. Use of external electric pacemaker in cardiac arrest. J Am Med Assoc . 1955;159:1428. - PubMed
    1. Vardas PE, et al. Guidelines for cardiac pacing and cardiac resynchronization therapy. The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. Europace. 2007;9:959. - PubMed
    1. Mond HG, et al. The world survey of cardiac pacing and cardioverter defibrillators: calendar year 2001. Pacing Clin Electrophysiol . 2004;27:955. - PubMed
    1. Uslan DZ, et al. Temporal trends in permanent pacemaker implantation: a population-based study. Am Heart J . 2008;155:896. - PMC - PubMed
    1. Andersen HR, et al. Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome. Lancet . 1997;350:1210. - PubMed

LinkOut - more resources