Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec;22(9):757-62.
doi: 10.1097/IJG.0b013e31825af58a.

Ability of optical coherence tomography-determined ganglion cell complex thickness to total retinal thickness ratio to diagnose glaucoma

Affiliations

Ability of optical coherence tomography-determined ganglion cell complex thickness to total retinal thickness ratio to diagnose glaucoma

Yoshiyuki Kita et al. J Glaucoma. 2013 Dec.

Abstract

Purpose: To evaluate the usefulness of the spectral-domain optical coherence tomography (SD OCT)-determined ganglion cell complex thickness to total retinal thickness ratio (G/T ratio) in diagnosing glaucoma.

Methods: A total of 99 eyes with primary open-angle glaucoma and 35 normal eyes were enrolled in the study. SD OCT (RTVue-100) was used to measure the macular ganglion cell complex thickness, total retinal thickness, outer retinal thickness, and circumpapillary retinal nerve fiber layer (RNFL) thickness. A new macular parameter, the G/T ratio, was also calculated. The ability of each parameter to diagnose glaucoma was examined by analyzing the area under the receiver operating characteristics curve (AUROC) and the sensitivity at fixed specificity.

Results: The G/T ratio was 36.0 ± 1.5% in normal eyes, 31.8 ± 1.7% in early glaucoma, and 30.2 ± 2.6% in advanced glaucoma. These decreases in the ratio were statistically significant. For the AUROC, the individual SD OCT parameters were 0.982 for the G/T ratio, 0.968 for the macular ganglion cell complex thickness, 0.942 for the RNFL thickness, and 0.841 for the total retinal thickness. The AUROC for the G/T ratio was significantly higher than that seen for the total retinal and RNFL thicknesses (P<0.05). Analyses of the sensitivity at a specificity of >90% indicated that the G/T ratio (sensitivity, 93.94%) was the best diagnostic parameter.

Conclusions: Decreases in the G/T ratio occur during the early stages of glaucoma. When using SD OCT to diagnose glaucoma, the G/T ratio may improve the diagnostic ability of the macular parameter.

PubMed Disclaimer

Publication types

LinkOut - more resources