Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples
- PMID: 22673812
- DOI: 10.1016/j.chroma.2012.05.059
Zirconia coated stir bar sorptive extraction combined with large volume sample stacking capillary electrophoresis-indirect ultraviolet detection for the determination of chemical warfare agent degradation products in water samples
Abstract
In this study, a sensitive, selective and reliable analytical method by combining zirconia (ZrO₂) coated stir bar sorptive extraction (SBSE) with large volume sample stacking capillary electrophoresis-indirect ultraviolet (LVSS-CE/indirect UV) was developed for the direct analysis of chemical warfare agent degradation products of alkyl alkylphosphonic acids (AAPAs) (including ethyl methylphosphonic acid (EMPA) and pinacolyl methylphosphonate (PMPA)) and methylphosphonic acid (MPA) in environmental waters. ZrO₂ coated stir bar was prepared by adhering nanometer-sized ZrO₂ particles onto the surface of stir bar with commercial PDMS sol as adhesion agent. Due to the high affinity of ZrO₂ to the electronegative phosphonate group, ZrO₂ coated stir bars could selectively extract the strongly polar AAPAs and MPA. After systematically optimizing the extraction conditions of ZrO₂-SBSE, the analytical performance of ZrO₂-SBSE-CE/indirect UV and ZrO₂-SBSE-LVSS-CE/indirect UV was assessed. The limits of detection (LODs, at a signal-to-noise ratio of 3) obtained by ZrO₂-SBSE-CE/indirect UV were 13.4-15.9 μg/L for PMPA, EMPA and MPA. The relative standard deviations (RSDs, n=7, c=200 μg/L) of the corrected peak area for the target analytes were in the range of 6.4-8.8%. Enhancement factors (EFs) in terms of LODs were found to be from 112- to 145-fold. By combining ZrO₂ coating SBSE with LVSS as a dual preconcentration strategy, the EFs were magnified up to 1583-fold, and the LODs of ZrO₂-SBSE-LVSS-CE/indirect UV were 1.4, 1.2 and 3.1 μg/L for PMPA, EMPA, and MPA, respectively. The RSDs (n=7, c=20 μg/L) were found to be in the range of 9.0-11.8%. The developed ZrO₂-SBSE-LVSS-CE/indirect UV method has been successfully applied to the analysis of PMPA, EMPA, and MPA in different environmental water samples, and the recoveries for the spiked water samples were found to be in the range of 93.8-105.3%.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.J Chromatogr A. 2013 Oct 4;1310:21-30. doi: 10.1016/j.chroma.2013.08.047. Epub 2013 Aug 20. J Chromatogr A. 2013. PMID: 23992883
-
A sol-gel polydimethylsiloxane/polythiophene coated stir bar sorptive extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples.J Chromatogr A. 2013 Feb 1;1275:25-31. doi: 10.1016/j.chroma.2012.12.036. Epub 2012 Dec 22. J Chromatogr A. 2013. PMID: 23312555
-
Analysis of preservatives with different polarities in beverage samples by dual-phase dual stir bar sorptive extraction combined with high-performance liquid chromatography.J Chromatogr A. 2013 Feb 22;1278:8-15. doi: 10.1016/j.chroma.2012.12.061. Epub 2013 Jan 8. J Chromatogr A. 2013. PMID: 23336943
-
Stir bar sorptive extraction for trace analysis.J Chromatogr A. 2007 Jun 8;1152(1-2):54-69. doi: 10.1016/j.chroma.2007.01.032. Epub 2007 Jan 13. J Chromatogr A. 2007. PMID: 17239895 Review.
-
Stir-bar sorptive extraction: A view on method optimisation, novel applications, limitations and potential solutions.J Chromatogr A. 2010 Apr 16;1217(16):2642-66. doi: 10.1016/j.chroma.2009.12.051. Epub 2010 Jan 4. J Chromatogr A. 2010. PMID: 20083248 Review.
Cited by
-
Controllable in situ growth of novel octahedral TiO2 nanoparticles on nickel/titanium alloy fiber substrate for selective solid-phase microextraction of ultraviolet filters in water samples.RSC Adv. 2022 Apr 19;12(19):11933-11941. doi: 10.1039/d2ra01031c. eCollection 2022 Apr 13. RSC Adv. 2022. PMID: 35481081 Free PMC article.
-
Quantitation of five organophosphorus nerve agent metabolites in serum using hydrophilic interaction liquid chromatography and tandem mass spectrometry.Anal Bioanal Chem. 2014 Aug;406(21):5195-202. doi: 10.1007/s00216-014-7702-2. Epub 2014 Mar 15. Anal Bioanal Chem. 2014. PMID: 24633507 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical