Determination of imatinib mesylate and related compounds by field amplified sample stacking with large volume sample injection capillary electrophoresis
- PMID: 22677653
- DOI: 10.1016/j.jpba.2012.05.010
Determination of imatinib mesylate and related compounds by field amplified sample stacking with large volume sample injection capillary electrophoresis
Abstract
Imatimib mesylate is a drug for the treatment of gastrointestinal stroma tumor and chronic myelogenous leukemia. In this study, capillary electrophoretic analysis of imatinib mesylate and related compounds was developed. The optimized separation condition was NaH(2)PO(4) (10 mM) aqueous solution containing 5 mM of 2-hydroxypropyl-β-cyclodextrin at a pH of 2.0. The separation could be obtained in less than 20 min when the separation voltage was 20 kV. To enhance the sensitivity, field amplified sample stacking combining with large volume sample injection was adopted. The optimal injection conditions were obtained by using methanol containing 0.5 mM HCl as the sample dilution solution and performing injection at a voltage of 15 kV for 60 s. The linearity ranges of ima amine, N-desmethyl imatinib and imatinib mesylate were 0.005-0.500 μg/ml, and 4-chloromethyl-N-(4-methyl-3-((4-(pyridin-3-yl) pyrimidin-2-yl) amino) phenyl) benzamide was 0.010-0.500 μg/ml, with good linear correlation coefficients (r(2)>0.9900). The intra-day and inter-day relative standard deviations of peak areas were satisfactory. Under the optimized condition, five batches of the synthesized samples were detected and ima amine was found in all the batches. Due to its simplicity, effectiveness and low price, the developed method can be used for quality control analysis of imatinib mesylate.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Nonaqueous capillary electrophoresis of imatinib mesylate and related substances.J Sep Sci. 2012 Aug;35(16):2108-13. doi: 10.1002/jssc.201200114. Epub 2012 Jul 2. J Sep Sci. 2012. PMID: 22753368
-
Identification of imatinib mesylate degradation products obtained under stress conditions.J Pharm Biomed Anal. 2007 Apr 11;43(5):1682-91. doi: 10.1016/j.jpba.2006.12.033. Epub 2007 Jan 12. J Pharm Biomed Anal. 2007. PMID: 17307328
-
Stability-indicating HPTLC determination of imatinib mesylate in bulk drug and pharmaceutical dosage form.J Pharm Biomed Anal. 2007 Jan 17;43(2):722-6. doi: 10.1016/j.jpba.2006.07.022. Epub 2006 Aug 22. J Pharm Biomed Anal. 2007. PMID: 16920319
-
Imatinib mesylate.Profiles Drug Subst Excip Relat Methodol. 2014;39:265-97. doi: 10.1016/B978-0-12-800173-8.00006-4. Profiles Drug Subst Excip Relat Methodol. 2014. PMID: 24794909 Review.
-
Capillary electrophoresis application in the analysis of the anti-cancer drugs impurities.Acta Pol Pharm. 2013 Mar-Apr;70(2):171-80. Acta Pol Pharm. 2013. PMID: 23614272 Review.
Cited by
-
Microwave-assisted solid-phase synthesis of nitrogen-doping carbon dot with good solvent compatibility and its sensing of sunitinib.Anal Bioanal Chem. 2021 Oct;413(25):6435-6447. doi: 10.1007/s00216-021-03609-9. Epub 2021 Aug 17. Anal Bioanal Chem. 2021. PMID: 34401928
-
A Modified Electrochemical Sensor Based on N,S-Doped Carbon Dots/Carbon Nanotube-Poly(Amidoamine) Dendrimer Hybrids for Imatinib Mesylate Determination.Biosensors (Basel). 2023 May 15;13(5):547. doi: 10.3390/bios13050547. Biosensors (Basel). 2023. PMID: 37232908 Free PMC article.
-
Detection of Imatinib Based on Electrochemical Sensor Constructed Using Biosynthesized Graphene-Silver Nanocomposite.Front Chem. 2021 Apr 22;9:670074. doi: 10.3389/fchem.2021.670074. eCollection 2021. Front Chem. 2021. PMID: 33968906 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources