Long-term outcomes of cardiovascular implantable electronic devices in patients with Staphylococcus aureus bacteremia
- PMID: 22679927
- DOI: 10.1111/j.1540-8159.2012.03438.x
Long-term outcomes of cardiovascular implantable electronic devices in patients with Staphylococcus aureus bacteremia
Abstract
Background: The use of cardiovascular implantable electronic devices (CIEDs) is increasing. Staphylococcus aureus bacteremia (SAB) poses a risk for hematogenous seeding of the device. Our aim is to identify risk factors associated with secondary CIED infection, due to hematogenous seeding, during SAB from an unrelated primary focus.
Methods: All patients with SAB and CIED were screened. Patients with SAB due to a primary source unrelated to the CIED were included. Patients were classified into cases if CIED infection was documented and controls without CIED infection during a minimum of 12 weeks follow-up. A retrospective review of patients' charts was done.
Results: Thirty patients with CIED and SAB from an unrelated focus were identified. CIED infection developed in 11 patients (36.7%). No significant differences were noted between cases and controls in the source, time-to-therapy, and time-to-intervene but infected devices were more likely to be implantable cardioverter-defibrillators (ICD) versus permanent pacemakers (PPMs) (9/11 [81.8%] vs 2/11 [18.2%] respectively, crude odds ratio 12.6, 95% confidence interval 10.8-14.4; P = 0.003).
Conclusion: Hematogenous seeding of a CIED during SAB from an unrelated focus is not uncommon. The risk factors for CIED seeding are unknown but ICD devices seem to be at greater risk when compared to PPM. The reasons are not yet clear. Larger studies are needed to better define risk factors and design preventive measures.
©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Similar articles
-
Cardiovascular implantable electronic device infection in patients with Staphylococcus aureus bacteremia.Pacing Clin Electrophysiol. 2010 Apr;33(4):407-13. doi: 10.1111/j.1540-8159.2009.02565.x. Epub 2009 Sep 30. Pacing Clin Electrophysiol. 2010. PMID: 19793360
-
Predicting risk of endovascular device infection in patients with Staphylococcus aureus bacteremia (PREDICT-SAB).Circ Arrhythm Electrophysiol. 2015 Feb;8(1):137-44. doi: 10.1161/CIRCEP.114.002199. Epub 2014 Dec 12. Circ Arrhythm Electrophysiol. 2015. PMID: 25504648 Free PMC article.
-
Outcomes in patients with cardiovascular implantable electronic devices and bacteremia caused by Gram-positive cocci other than Staphylococcus aureus.Circ Arrhythm Electrophysiol. 2010 Dec;3(6):639-45. doi: 10.1161/CIRCEP.110.957514. Epub 2010 Sep 18. Circ Arrhythm Electrophysiol. 2010. PMID: 20852296
-
Contemporary management of cardiovascular implantable electronic device infections.Expert Rev Anti Infect Ther. 2010 Jul;8(7):831-9. doi: 10.1586/eri.10.54. Expert Rev Anti Infect Ther. 2010. PMID: 20586567 Review.
-
Management of bacteremia in patients living with cardiovascular implantable electronic devices.Heart Rhythm. 2016 Nov;13(11):2247-2252. doi: 10.1016/j.hrthm.2016.08.029. Epub 2016 Aug 19. Heart Rhythm. 2016. PMID: 27546815 Review.
Cited by
-
Risk of Cardiac Implantable Electronic Device Infection in Patients with Bloodstream Infection: Microbiologic Effect in the Era of Positron Emission Tomography-Computed Tomography.Curr Cardiol Rep. 2023 Aug;25(8):781-793. doi: 10.1007/s11886-023-01900-y. Epub 2023 Jun 23. Curr Cardiol Rep. 2023. PMID: 37351825 Review.
-
Clinical Approach to Evaluation of Underlying Cardiac Device Infection in Patients Hospitalized with Bacteremia.Methodist Debakey Cardiovasc J. 2023 Aug 1;19(4):48-57. doi: 10.14797/mdcvj.1271. eCollection 2023. Methodist Debakey Cardiovasc J. 2023. PMID: 37547899 Free PMC article. Review.
-
Current Management of Cardiac Implantable Electronic Device Infections by Infectious Disease Specialists.Clin Infect Dis. 2016 Oct 15;63(8):1072-1075. doi: 10.1093/cid/ciw431. Epub 2016 Jun 28. Clin Infect Dis. 2016. PMID: 27358347 Free PMC article.
-
Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection.Open Forum Infect Dis. 2019 Feb 21;6(4):ofz084. doi: 10.1093/ofid/ofz084. eCollection 2019 Apr. Open Forum Infect Dis. 2019. PMID: 30997366 Free PMC article.
-
Staphylococcus aureus infections: epidemiology, pathophysiology, clinical manifestations, and management.Clin Microbiol Rev. 2015 Jul;28(3):603-61. doi: 10.1128/CMR.00134-14. Clin Microbiol Rev. 2015. PMID: 26016486 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources